EDS-G509
Full Gigabit 9G-port Managed Ethernet Switch
Technology |
|
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100Base FX
IEEE 802.3ab for 1000BaseT(X)
IEEE 802.3z for 1000BaseSX/LX/LHX/ZX/EZX
IEEE 802.3x for Flow Control
IEEE 802.1D for Spanning Tree Protocol
IEEE 802.1w for Rapid STP
IEEE 802.1Q for VLAN Tagging
IEEE 802.1p for Class of Service
IEEE 802.1X for Authentication
IEEE 802.3ad for Port Trunk with LACP |
|
|
|
| IGMPv1/v2 device, GMRP, GVRP, SNMPv1/v2c/v3, DHCP Server/Client, DHCP Option 82, BootP, TFTP, SNTP, SMTP, RARP, RMON, HTTP, HTTPS, Telnet, SSH, Syslog, SNMP Inform, Modbus/TCP |
|
|
|
| MIB-II, Ethernet-Like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9 |
|
|
|
| IEEE 802.3x flow control, back pressure flow control |
|
|
Priority Queues: 4
Max. Number of Available VLANs: 64
VLAN ID Range: VID 1 to 4094
IGMP Groups: 256 |
|
|
Interface |
|
10/100/1000BaseT(X) auto negotiation speed |
|
|
|
|
|
|
|
| PWR1, PWR2, FAULT, 10/100/1000M, MASTER, COUPLER |
|
|
| Turbo Ring, Master, Coupler, Reserve |
|
|
| Two relay outputs with current carrying capacity of 1A @ 24 VDC |
|
|
2 inputs with the same ground, but electrically isolated from the electronics.
• +13 to +30V for state “1”
• -30 to +3V for state “0”
• Max. input current: 8 mA |
|
|
Power |
|
12/24/48 VDC, 24 VAC (18 to 30 VAC), redundant dual inputs
|
|
|
|
| Two removable 6-pin terminal blocks |
|
|
| Overload Current Protection |
|
|
| Reverse Polarity Protection |
|
|
|
Mechanical |
|
|
|
87.1 x 135 x 107 mm
(4.34 x 5.31 x 4.21 in) |
|
|
|
|
|
| DIN-Rail, Wall Mounting (optional kit) |
|
|
Environmental |
|
0 to 60°C (32 to 140°F),
-40 to 75°C (-40 to 167°F) for T models |
|
|
|
| -40 to 85 °C (-40 to 185°F) |
|
|
| Ambient Relative Humidity |
|
| 5% to 95% (non-condensing) |
|
|
|
Regulatory Approvals |
|
UL508 (Pending), EN60950-1 (Pending)
|
|
|
|
UL/cUL Class I, Division 2, Groups A, B, C, and D (Pending);
ATEX Class I, Zone 2, Ex nC IIC (Pending) |
|
|
|
| DNV (Pending), GL (Pending) |
|
|
|
| FCC Part 15, CISPR (EN55022) class A |
|
|
EN61000-4-2 (ESD), level 3
EN61000-4-3 (RS), level 3
EN61000-4-4 (EFT), level 2
EN61000-4-5 (Surge), level 3
EN61000-4-6 (CS), level 3
EN61000-4-8
EN61000-4-11 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|