Location: Home >> Products >> Industrial Ethernet >> Industrial Ethernet Switches >> Managed Ethernet Switches >> EDS-518A Series

EDS-518A Series

16+2G-port Gigabit managed Ethernet switches

Datasheet
Manual
Drivers & Software
Larger image
 


Features
Specifications
Ordering Information

Features and Benefits

  • Turbo Ring (recovery time < 20 ms at full load) and RSTP/STP (IEEE 802.1w/D) 
  • IGMP snooping and GMRP for filtering multicast traffic
  • Port-based VLAN, IEEE 802.1Q VLAN and GVRP to ease network planning
  • QoS-IEEE 802.1p and TOS/DiffServ to increase determinism
  • Port Trunking for optimum bandwidth utilization
  • IEEE 802.1X , HTTPS, and SSH to enhance network security
  • SNMPv1/v2c/v3 for different levels of network management
  • RMON for efficient network monitoring and proactive capability
  • Bandwidth management prevents unpredictable network status
  • ABC-01 (Automatic Backup Configurator) for system configuration backup
  • Port mirroring for online debugging
  • Automatic warning through e-mail and relay output
  • Digital inputs to integrate sensors and alarms with IP networks
  • DIN-Rail or panel mounting capability

Introduction

The EDS-518A is a standalone 18-port managed Ethernet switch that provides 2 combo Gigabit ports with built-in RJ45 ports or SFP slots for Gigabit fiber optic communication, and Ethernet Redundant Turbo Ring (recovery time < 20 ms) to increase the reliability and speed of your network backbone. The EDS-518A also supports intelligent network management functions, including QoS, IGMP Snooping/GMRP, VLAN, Port Trunking, SNMPv1/v2c/v3, IEEE 802.1X, HTTPS, and SSH.


More info >>

•  Technology:
StandardsIEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X) and 100Base FX,
IEEE 802.3x for Flow Control,
IEEE 802.1D for Spanning Tree Protocol,
IEEE 802.1w for Rapid STP,
IEEE 802.1Q for VLAN Tagging,
IEEE 802.1p for Class of Service,
IEEE 802.1X for Authentication,
IEEE 802.3ad for Port Trunk with LACP,
IEEE 802.3ab for 1000BaseT(X),
IEEE 802.3z for 1000BaseSX/LX/LHX/ZX
ProtocolsIGMPv1/v2 device, GMRP, GVRP, SNMPv1/v2c/v3, DHCP Server/Client, DHCP Option 82, BootP, TFTP, SNTP, SMTP, RARP, RMON, HTTP, HTTPS, Telnet, SSH, Syslog
MIBMIB-II, Ethernet-Like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9
Flow ControlIEEE802.3x flow control, back pressure flow control Interface


•  Switch Properties:
Priority Queues4
IGMP Groups256
Max. Number of Available VLANs64
VLAN ID RangeVID 1 to 4094


•  Interface:
RJ45 Ports10/100BaseT(X) or 10/100/1000BaseT(X) auto negotiation speed
Fiber Port(s)100BaseFX (SC/ST connector), and 1000BaseSFP slot
ConsoleRS-232 (RJ45)
LED IndicatorsPWR1, PWR2, FAULT, 10/100M (TP port), 100M (Fiber port), MASTER, COUPLER
Alarm ContactTwo relay outputs with current carrying capacity of 1A @ 24 VDC
Digital InputsTwo inputs with the same ground, but electrically isolated from the electronics
•+13 to +30V for state “1”
•-30 to +3V for state “0”
•Max. input current: 8 mA

•  Optical Fiber

•  Power Requirements:
Input Voltage24 VDC (12 to 45 VDC), redundant dual inputs
Input Current(@24V): 0.51A (EDS-518A), 0.61A (EDS-518A-MM, EDS-518A-SS)
Overload Current ProtectionPresent
ConnectionTwo removable 6-pin terminal blocks
Reverse Polarity ProtectionPresent


•  Physical Characteristics:
EnclosureIP30 protection
HousingMetal case
Weight 1630 g
Dimensions94 x 135 x 142.7 mm (3.74 x 5.31 x 5.62 in.)
InstallationDIN-Rail Mounting, Wall Mounting (optional kit)


•  Environmental Limits:
Operating Temperature0 to 60°C (32 to 140°F)

-40 to 75°C (-40 to 167°F) for T models
Storage Temperature-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity5 to 95% (non-condensing)


• Regulatory Approvals
SafetyUL508, UL60950-1, CSA C22.2 No. 60950-1, EN60950-1
EMIFCC Part 15, CISPR (EN55022) class A
EMSEN61000-4-2 (ESD), level 2
EN61000-4-3 (RS), level 3
EN61000-4-4 (EFT), level 2
EN61000-4-5 (Surge), level 3
EN61000-4-6 (CS), level 3
EN61000-4-8
EN61000-4-11
EN61000-4-12
Hazardous LocationUL/cUL Class I, Division 2, Groups A, B, C, and D (Pending); ATEX Class I, Zone 2, EEx nC IIC (Pending)
ShockIEC 60068-2-27
FreefallIEC 60068-2-32
VibrationIEC 60068-2-6
MaritimeDNV, GL
MTBF (meantime between failures)240,000 hrs
Database: Telcordia (Bellcore), GB


•  Warranty:
Warranty Period5 years
DetailsSee www.moxa.com/warranty



To request a quote, indicate which items you are interested in below and click "Get a Quote".
Managed Ethernet Switches
 Model No. Description

EDS-518A

Industrial Gigabit Managed Redundant Ethernet Switch with 16 10/100BaseT(X) ports, 2 combo 10/100/1000BaseT(X) / SFP (mini-GBIC) ports, 0 to 60°C

EDS-518A-MM-SC

Industrial Gigabit Managed Redundant Ethernet Switch with 14 10/100BaseT(X) ports, 2 multi mode 100BaseFX ports, SC connector, and 2 combo 10/100/1000BaseT(X) / SFP (mini-GBIC) ports, 0 to 60°C

EDS-518A-MM-ST

Industrial Gigabit Managed Redundant Ethernet Switch with 14 10/100BaseT(X) ports, 2 multi mode 100BaseFX ports, ST connector, and 2 combo 10/100/1000BaseT(X) / SFP (mini-GBIC) ports, 0 to 60°C

EDS-518A-SS-SC

Industrial Gigabit Managed Redundant Ethernet Switch with 14 10/100BaseT(X) ports, 2 single mode 100BaseFX ports, SC connector, and 2 combo 10/100/1000BaseT(X) / SFP (mini-GBIC) ports, 0 to 60°C

EDS-518-SS-SC-80

Industrial Gigabit Managed Redundant Ethernet Switch with 14 10/100BaseT(X) ports, 2 long-haul (80 km) single mode 100BaseFX ports, SC connector, and 2 combo 10/100/1000BaseT(X) / SFP (mini-GBIC) ports, 0 to 60°C

Managed Ethernet Switches - Extended Temperature
 Model No. Description

EDS-518A-T

Industrial Gigabit Managed Redundant Ethernet Switch with 16 10/100BaseT(X) ports, 2 combo 10/100/1000BaseT(X) / SFP (mini -GBIC) ports, -40 to 75°C

EDS-518A-MM-SC-T

Industrial Gigabit Managed Redundant Ethernet Switch with 14 10/100BaseT(X) ports, 2 multi mode 100BaseFX ports, SC connector, and 2 combo 10/100/1000BaseT(X) / SFP (mini-GBIC) ports, -40 to 75°C

EDS-518A-MM-ST-T

Industrial Gigabit Managed Redundant Ethernet Switch with 14 10/100BaseT(X) ports, 2 multi mode 100BaseFX ports, ST connector, and 2 combo 10/100/1000BaseT(X) / SFP (mini-GBIC) ports, -40 to 75°C

EDS-518A-SS-SC-T

Industrial Gigabit Managed Redundant Ethernet Switch with 14 10/100BaseT(X) ports, 2 single mode 100BaseFX ports, SC connector, and 2 combo 10/100/1000BaseT(X) / SFP (mini-GBIC) ports, -40 to 75°C

Backup Configurators
 Model No. Description

ABC-01

Automatic Backup Configurator through the RS-232 console port, 0 to 60°C

Mounting Kits
 Model No. Description

RK-4U

4U-high 19” rack mounting kit

WK-46

Wall Mounting Kit

SFP Modules
 Model No. Description

SFP-1GSXLC

SFP module with 1 1000BaseSX port with LC connector for 0.5 km transmission, 0 to 60°C

SFP-1GLSXLC

SFP module with 1 1000BaseSX port with LC connector for 2 km transmission, 0 to 60°C

SFP-1GLXLC

SFP module with 1 1000BaseLX port with LC connector for 10 km transmission, 0 to 60°C

SFP-1GLHXLC

SFP module with 1 1000BaseLHX port with LC connector for 40 km transmission, 0 to 60°C

SFP-1GZXLC

SFP module with 1 1000BaseZX port with LC connector for 80 km transmission, 0 to 60°C

SFP-1GEZXLC

SFP module with 1 1000BaseEZX port with LC connector for 110 km transmission, 0 to 60°C

SFP-1G10ALC

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission, TX 1310 nm, RX 1550 nm, 0 to 60°C

SFP-1G10BLC

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission, TX 1550 nm, RX 1310 nm, 0 to 60°C

SFP-1G20ALC

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission, TX 1310 nm, RX 1550 nm, 0 to 60°C

SFP-1G20BLC

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission, TX 1550 nm, RX 1310 nm, 0 to 60°C

SFP-1G40ALC

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission, TX 1310 nm, RX 1550 nm, 0 to 60°C

SFP-1G40BLC

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission, TX 1550 nm, RX 1310 nm, 0 to 60°C

SFP-1GSXLC-T

SFP module with 1 1000BaseSX port with LC connector for 0.5 km transmission, -20 to 75°C

SFP-1GLXLC-T

SFP module with 1 1000BaseLX port with LC connector for 10 km transmission, -40 to 85°C

SFP-1GLHXLC-T

SFP module with 1 1000BaseLHX port with LC connector for 40 km transmission, -40 to 85°C

SFP-1GZXLC-T

SFP module with 1 1000BaseZX port with LC connector for 80 km transmission, -40 to 85°C

SFP-1G10ALC-T

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission, TX 1310 nm, RX 1550 nm, -40 to 85°C

SFP-1G10BLC-T

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission, TX 1550 nm, RX 1310 nm, -40 to 85°C

SFP-1G20ALC-T

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission, TX 1310 nm, RX 1550 nm, -40 to 85°C

SFP-1G20BLC-T

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission, TX 1550 nm, RX 1310 nm, -40 to 85°C

SFP-1G40ALC-T

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission, TX 1310 nm, RX 1550 nm, -40 to 85°C

SFP-1G40BLC-T

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission, TX 1550 nm, RX 1310 nm, -40 to 85°C

DIN-Rail Power Supplies
 Model No. Description

DR-4524

45W/2A DIN-Rail 24 VDC power supply, 85 to 264 VAC input

DR-75-24

75W/3.2A DIN-Rail 24 VDC power supply, 85 to 264 VAC input

DR-120-24

120W/5A DIN-Rail 24 VDC power supply, 88 to 132 VAC/176 to 264 VAC input by switch

Accessories - SNMP OPC Server Pro Software
 Model No. Description

EDS-SNMP OPC Server Pro

CD with EDS-SNMP OPC Server Pro Software and Manual