SPL-24 Series
IEEE802.3af PoE Splitter
![]() |
|
|
|
|
Features and Benefits
IntroductionWith the technology of PoE, we can transfer both data and electrical power to Ethernet-enabled devices using a standard Ethernet CAT5 cable. SPL-24 plays the role of powered devices (PD) and splits power from PoEto Ethernet devices. In this case, both power and data can be transmitted up to 328 feet (100 m) from power source equipment (PSE). This product can operate from 0 to 60°C or -40 to 75°C for T model, and the rugged hardware design makes SPL-24 perfect for ensuring your PoE Ethernet equipment can meet demanding industrial applications. More info >> |
| • Technology: | |
| Standards | IEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X) and 100BaseFX, IEEE 802.3af for Power-over-Ethernet |
| • Interface: | |
| RJ45 Ports | 10/100BaseT(X) for PoE IN and DATA OUT |
| LED Indicators | Power |
| • Power Requirements: | |
| Input Voltage | 44 to 75 VDC |
| Output Voltage | 24 VDC |
| Output Power | 12.95W (0.54A @ 24 VDC) |
| Overload Current Protection | 400 mA (@ 48 VDC input) |
| Connection | Removable 3-pin terminal block for output |
| Efficiency | 85% (at 25°C, fully loaded) |
| • Physical Characteristics: | |
| Enclosure | IP30 protection, plastic case |
| Weight | 95 g |
| Dimensions | 24.87 x 100 x 74 mm (0.98 x 4.29 x 2.91 in) |
| Installation | DIN-Rail mounting |
| • Environmental Limits: | |
| Operating Temperature | 0 to 60°C (32 to 140°F) -40 to 75°C (-40 to 167°F) for T model |
| Storage Temperature | -40 to 85°C (-40 to 185°F) |
| Ambient Relative Humidity | 5 to 95% (non-condensing) |
| • Agency Approvals: | |
| EMI | FCC Part 15, CISPR (EN55022) class A |
| EMS | EN61000-4-2 (ESD), level 3 EN61000-4-3 (RS), level 3 EN61000-4-4 (EFT), level 3 EN61000-4-5 (Surge), level 3 EN61000-4-6 (CS), level 3 EN61000-4-8 EN61000-4-11 |
| Safety | UL 508 (Pending) |
| Hazardous Location | UL/cUL Class I, Division 2, Groups A, B, C and D(Pending); ATEX Class 1, Zone 2, EEx nC IIC (Pending) |
| Shock | IEC60068-2-27 |
| Freefall | IEC60068-2-32 |
| Vibration | IEC60068-2-6 |
| MTBF (meantime between failures) | 5,100,000 hrs Database: MIL-HDBK-217F, GB 25˚C |
| • Warranty: | |
| Warranty Period | 5 years |