OnCell G2111/G2151I Series

Industrial quad-band GSM/GPRS modems

moxa-oncell-g2111-g2151i-series-image-1-(1).jpg | Moxa

Features and Benefits

  • Quad-band GSM/GPRS 850/900/1800/1900 MHz
  • DIN-rail mounting and wall mounting
  • 2.5 kV RMS isolation for 1 min. for all serial signals (G2151I only)
  • LED indicators for GSM/GPRS and data transmission status
  • Extended operating temperature from -25 to 70°C (G2111-T only)

Certifications

  • moxa-ul-listed-certification-logo-image.png | Moxa
  • moxa-ce-certification-logo-image.png | Moxa
  • moxa-fcc-certification-logo-image.png | Moxa
 
Contact Sales

Introduction

The OnCell G2111/G2151I Series of industrial quad-band GSM/GPRS modems are designed to transmit data and short messages (SMS) over GSM/GPRS mobile networks. The modems can be used to increase the efficiency of maintenance and communication, but do not require extensive training. In addition, the modems can be mounted on a DIN rail or wall. The OnCell G2111/G2151I Series modems accept a 12 to 48 VDC power input, making them suitable for use with a variety of field power sources.

The serial ports feature 15 kV ESD line protection to protect the products from harmful electrical discharge, and separate RS-232 and RS-422/485 interfaces are built into the OnCell G2151I, each with 2.5 kV RMS isolation protection for one minute. The two serial interfaces on the OnCell G2151I make it ideal for attaching all kinds of devices, such as stand-alone controllers, PC COM ports, and multi-dropped electric meters. In addition, the OnCell G2111-T has an extended operating temperature (-25 to 70°C) design that makes it suitable for heavy industrial use.

  • Cellular Standards

    GSM, GPRS

  • Band Options

    Quad-band GSM/GPRS 850 MHz / 900 MHz / 1800 MHz / 1900 MHz

  • GPRS Multi-Slot Class

    10

  • GPRS Terminal Device Class

    Class B

  • GPRS Coding Schemes

    CS1 to CS4

  • CSD Data Rates

    Up to 14400 bps

  • Cellular Antenna Connectors

    1 SMA female

  • No. of SIMs

    1

  • SIM Control Voltage

    3 V

  • No. of Ports

    1

  • Serial Standards

    All models: RS-232 (DB9 female connector)
    OnCell G2151I: RS-232/422/485 (5-pin terminal block connector)

  • ESD Protection

    OnCell G2111: 15 kV

  • Isolation

    OnCell G2151I: 2 kV

  • Data Bits

    8

  • Stop Bits

    1

  • Parity

    None

  • Flow Control

    RTS/CTS

  • Baudrate

    300 bps to 230.4 kbps

  • RS-232

    TxD, RxD, RTS, CTS, DTR, DSR, DCD, RI, GND

  • RS-422

    Tx+, Tx-, Rx+, Rx-, GND

  • RS-485-2w

    Data+, Data-, GND

  • RS-485-4w

    Tx+, Tx-, Rx+, Rx-, GND

  • Input Voltage

    12 to 48 VDC

  • Power Connector

    Terminal block

  • Input Current

    0.625 A @ 12 VDC, 0.16 A @ 48 VDC

  • Housing

    ABS + Polycarbonate

  • IP Rating

    IP30

  • Dimensions

    27 x 123 x 79 mm (1.06 x 4.84 x 3.11 in)

  • Weight

    155 g (0.34 lb)

  • Operating Temperature

    OnCell G2111/G2151I: -20 to 55°C (-4 to 131°F)
    OnCell G2111I-T: -25 to 70°C (-13 to 158°F)

  • Storage Temperature (package included)

    -40 to 75°C (-40 to 167°F)

  • Ambient Relative Humidity

    5 to 95% (non-condensing)

  • Safety

    UL 60950-1

  • EMC

    EN 55032/24

  • EMI

    CISPR 32, FCC Part 15B Class A

  • EMS

    IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
    IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
    IEC 61000-4-4 EFT: Power: 0.5 kV
    IEC 61000-4-5 Surge: Power: 1 kV
    IEC 61000-4-6 CS: 3 V
    IEC 61000-4-8 PFMF

  • Radio Frequency

    FCC Part 22H, FCC Part 24E, EN 301 489-1, EN 301 489-7, EN 301 511

  • Time

    OnCell G2111: 925,000 hrs
    OnCell G2111-T: 925,000 hrs
    OnCell G2151I: 864,000 hrs

  • Standards

    Telcordia SR332

Support Documents

Name Type Version Release Date
Datasheet for OnCell G2111/G2151I Series
723.5 KB
Datasheet v1.1 2019-03-28 Mar 28, 2019
Manual for OnCell G2111/G2151I Series
4.4 MB
Manual v2.1 2017-05-05 May 05, 2017
2D CAD for G2111 TOP
1.2 MB
2D CAD 2016-04-22 Apr 22, 2016
2D CAD for G2151I TOP
1.2 MB
2D CAD 2016-04-22 Apr 22, 2016
Manual for OnCell G2111/G2151I Series
2.6 MB
Manual v1.0 2012-02-09 Feb 09, 2012
Manual for OnCell G2111/G2151I Series (AT command list)
2.6 MB
Manual v1.0 2011-10-20 Oct 20, 2011
QIG for OnCell G2111/G2151I Series
220.4 KB
QIG v4.0 2008-07-16 Jul 16, 2008

Available Models (6)

Show Images
moxa-oncell-g2111-image.jpg | MoxaOnCell G2111moxa-oncell-g2111-t-image.jpg | MoxaOnCell G2111-Tmoxa-oncell-g2151i-image.jpg | MoxaOnCell G2151Imoxa-oncell-g2111-image.jpg | MoxaOnCell G2111
Cellular StandardGSM/GPRSGSM/GPRSGSM/GPRSGSM/GPRS
Band850/900/1800/1900 MHz850/900/1800/1900 MHz850/900/1800/1900 MHz850/900/1800/1900 MHz
Operating Temp.-20 to 55°C-25 to 70°C-20 to 55°C-20 to 55°C
Serial Isolation
Serial StandardsRS-232RS-232RS-232/422/485RS-232
Add to QuoteView BagAdd to QuoteView BagAdd to QuoteView BagAdd to QuoteView Bag
moxa-oncell-g2111-t-image.jpg | MoxaOnCell G2111-Tmoxa-oncell-g2151i-image.jpg | MoxaOnCell G2151I
Cellular StandardGSM/GPRSGSM/GPRS
Band850/900/1800/1900 MHz850/900/1800/1900 MHz
Operating Temp.-25 to 70°C-20 to 55°C
Serial Isolation
Serial StandardsRS-232/422/485RS-232/422/485
Add to QuoteView BagAdd to QuoteView Bag
Added To Bag

OnCell G2111/G2151I Series

OnCell G2111

moxa-oncell-g2111-image.jpg | Moxa

Buy online from our distributors

OnCell G2111/G2151I Series

OnCell G2111-T

moxa-oncell-g2111-t-image.jpg | Moxa

Buy online from our distributors

OnCell G2111/G2151I Series

OnCell G2151I

moxa-oncell-g2151i-image.jpg | Moxa

Buy online from our distributors

OnCell G2111/G2151I Series

OnCell G2111

moxa-oncell-g2111-image.jpg | Moxa

Buy online from our distributors

OnCell G2111/G2151I Series

OnCell G2111-T

moxa-oncell-g2111-t-image.jpg | Moxa

Buy online from our distributors

OnCell G2111/G2151I Series

OnCell G2151I

moxa-oncell-g2151i-image.jpg | Moxa

Buy online from our distributors