Location: Home >> Products >> Industrial Ethernet >> Industrial Ethernet Switches >> IEC 61850-3 Ethernet Switches >> PT-7710 Series

PT-7710 Series

IEC 61850-3 8+2G-port Gigabit modular managed Ethernet switches

Datasheet
Manual
Drivers & Software
Larger image
 


Features
Specifications
Ordering Information

Features and Benefits


  • Turbo Ring and RSTP/STP (IEEE 802.1W/D)
  • IGMP Snooping and GMRP for fi ltering multicast traffic from industrial Ethernet protocols
  • Port-based VLAN, IEEE 802.1Q VLAN, and GVRP protocol to ease network planning
  • QoS-IEEE802.1p/1Q and TOS/DiffServ to increase determinism
  • IEEE 802.1Q VLAN, and GVRP protocol to ease network planning
  • 802.3ad, LACP for optimum bandwidth utilization
  • IEEE 802.1X and https/SSL to enhance network security
  • SNMP V1/V2c/V3 for different levels of network management
  • RMON for efficient network monitoring and proactive capability
  • ABC-01 for system configuration backup
  • Bandwidth management prevents unpredictable network status
  • Lock port for only authorized MAC address access 
  • Port mirroring for online debugging
  • Automatic warning by exception through email, relay output
  • Automatic recovery of connected device's IP addresses
  • Line-swap fast recovery
  • Configurable by Web browser, Telnet/Serial console, Windows utility, and ABC-01

The PowerTrans PT-7710 is designed to meet the demands of power substation automation systems (IEC 61850-3, IEEE 1613), traffic control systems (NEMA TS2), and railway applications (EN50121-4). The PT-7710's Gigabit and fast Ethernet backbone, redundant ring, and 24/48 VDC dual redundant power supplies or 110/220 VDC/VAC power supplies increase the reliability of the communications and reduce cabling and wiring costs. The modular design of the PT-7710 makes network planning easy, and allows greater flexibility by letting you install up to 2 Gigabit ports and 8 fast Ethernet ports, or 10 fast Ethernet ports.

This product supports expansion modules. Click here for info on available modules.

More info >>

•  Technology:
StandardsIEEE 802.3 for 10BaseT,
IEEE 802.3u for 100BaseT(X) and 100BaseFX,
IEEE 802.3ab for 1000BaseT(X),
IEEE 802.3z for 1000BaseSX/LX/LHX/ZX,
IEEE 802.3x for Flow Control,
IEEE 802.1D for Spanning Tree Protocol,
IEEE 802.1w for Rapid STP,
IEEE 802.1Q for VLAN Tagging,
IEEE 802.1p for Class of Service,
IEEE 802.1X for Authentication,
IEEE 802.3ad for Port Trunk with LACP
ProtocolsIGMP v1/v2 device, GMRP, GVRP, SNMPv1/v2c/v3, DHCP Server/Client, DHCP Option 82, BootP, TFTP, SNTP, SMTP, RARP, RMON, HTTP, HTTPS, Telnet, SSH, Syslog
MIBMIB-II, Ethernet-like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9
Flow ControlIEEE 802.3x flow control, back pressure flow control


•  Switch Properties:
Priority Queues4
IGMP Groups256
Max. Number of Available VLANs64
VLAN ID RangeVID 1 to 4094


•  Interface:
Fast EthernetSlot 1 for any combination of 6, 7, or 8-port PM-7200 fast Ethernet modules with 10/100BaseT(X) or 100BaseFX (SC/ST connector), and Slot 2 for 1 or 2-port interface modules with 100BaseFX (SC/ST connector)
Click here for info on available modules.
Gigabit EthernetSlot 2 for 2-port PM-7200 Gigabit Ethernet combo module with 10/100/1000BaseT(X) or 1000BaseSFP slots
Click here for info on available modules.
ConsoleRS-232 (RJ45)
Alarm ContactOne relay output with current carrying capacity of 3A@30 VDC or 3A@240 VAC
System LED IndicatorsSTAT, PWR1, PWR2, FAULT, MASTER, COUPLER
Module LED IndicatorsLNK/ACT, FDX/HDX, RING PORT, COUPLER PORT, SPEED


•  Power Requirements:
Input Voltage24/48 VDC (9 to 60 V), or 110/220 VDC/VAC (88 to 300 VDC and 85 to 264 VAC)
Input Current(all ports are equipped with Fiber)
Max. 0.81A @ 24 VDC
Max. 0.42A @ 48 VDC
Max. 0.17/0.10 @ 110/220 VDC,
Max. 0.20/0.12 @ 110/220 VAC
Overload Current ProtectionPresent
Connection10-pin terminal block
Reverse Polarity ProtectionPresent


•  Physical Characteristics:
HousingIP30 protection
Weight 2200 g
Dimensions266.7 x 44 x 195 mm (10.5 x 1.73 x 7.68 in.)
Installation19" rack mounting, wall mounting


•  Agency Approvals:
EMIFCC Part 15, CISPR (EN55022) class A
SafetyEN60950-1 (Pending)
MaritimeDNV (Pending), GL (Pending)
Road TrafficNEMA TS2
Rail TrafficEN50121-4 (Pending)
Power AutomationIEC 61850-3, IEEE 1613


•  Environmental Limits:
Operating Temperature-40 to 85°C (-40 to 185°F)
Storage Temperature-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity5 to 95% (non-condensing)


• Warranty
Warranty Period5 years
DetailsSee www.moxa.com/warranty



To request a quote, indicate which items you are interested in below and click "Get a Quote".
Modular Switch Systems
 Model No. Description

PT-7710-D-HV

IEC 61850-3 modular managed Ethernet switch system with 1 slot for fast Ethernet modules, and 1 slot for fast Ethernet or Gigabit Ethernet modules, up to 10 or 8+2G ports, down cabling, 1 isolated power supply (88-300 VDC or 85-264 VAC), -40 to 85°C

PT-7710-F-LV

IEC 61850-3 modular managed Ethernet switch system with 1 slot for fast Ethernet modules, and 1 slot for fast Ethernet or Gigabit Ethernet modules, up to 10 or 8+2G ports, front cabling, 1 power supply (24/48 VDC), -40 to 85°C

PT-7710-D-LV

IEC 61850-3 modular managed Ethernet switch system with 1 slot for fast Ethernet modules, and 1 slot for fast Ethernet or Gigabit Ethernet modules, up to 10 or 8+2G ports, down cabling, 1 power supply (24/48 VDC), -40 to 85°C

PT-7710-F-HV

IEC 61850-3 modular managed Ethernet switch system with 1 slot for fast Ethernet modules, and 1 slot for fast Ethernet or Gigabit Ethernet modules, up to 10 or 8+2G ports, front cabling, 1 isolated power supply (88-300 VDC or 85-264 VAC), -40 to 85°C

PM-7200 series
 Model No. Description

PM-7200-1MSC

Fast Ethernet module with 1 100BaseFX multi-mode port with SC connector

PM-7200-2GTXSFP

Gigabit Ethernet module with 2 10/100/1000BaseT(X) or 1000BaseSFP slot combo ports (see the SFP-1G series ordering information for available SFP Gigabit Ethernet modules)

PM-7200-1MST

Fast Ethernet module with 1 100BaseFX multi-mode port with ST connector

PM-7200-1SSC

Fast Ethernet module with 1 100BaseFX single-mode port with SC connector

PM-7200-2MST

Fast Ethernet module with 2 100BaseFX multi-mode ports with ST connectors

PM-7200-2SSC

Fast Ethernet module with 2 100BaseFX single-mode ports with SC connectors

PM-7200-2MSC

Fast Ethernet module with 2 100BaseFX multi-mode ports with SC connectors

PM-7200-1LSC6TX

Fast Ethernet module with 1 100BaseFX single-mode port with SC connector for 80 km transmission and 6 10/100BaseT(X) ports

PM-7200-2MST4TX

Fast Ethernet module with 2 100BaseFX multi-mode ports with ST connectors and 4 10/100BaseT(X) ports

PM-7200-2MSC4TX

Fast Ethernet module with 2 100BaseFX multi-mode ports with SC connectors and 4 10/100BaseT(X) ports

PM-7200-2SSC4TX

Fast Ethernet module with 2 100BaseFX multi-mode ports with SC connectors and 4 10/100BaseT(X) ports

PM-7200-4MST2TX

Fast Ethernet module with 4 100BaseFX multi-mode ports with ST connectors and 2 10/100BaseT(X) ports

PM-7200-4MSC2TX

Fast Ethernet module with 4 100BaseFX multi-mode ports with SC connectors and 2 10/100BaseT(X) ports

PM-7200-4SSC2TX

Fast Ethernet module with 4 100BaseFX single-mode ports with SC connectors and 2 10/100BaseT(X) ports

PM-7200-6MST

Fast Ethernet module with 6 100BaseFX multi-mode ports with ST connectors

PM-7200-6MSC

Fast Ethernet module with 6 100BaseFX multi-mode ports with SC connectors

PM-7200-6SSC

Fast Ethernet module with 6 100BaseFX single-mode ports with SC connectors

PM-7200-8TX

Fast Ethernet module with 8 10/100BaseT(X) ports

SFP Modules
 Model No. Description

SFP-1GSXLC

SFP module with 1 1000BaseSX port with LC connector for 0.5 km transmission, 0 to 60°C

SFP-1GLSXLC

SFP module with 1 1000BaseSX port with LC connector for 2 km transmission, 0 to 60°C

SFP-1GLXLC

SFP module with 1 1000BaseLX port with LC connector for 10 km transmission, 0 to 60°C

SFP-1GLHXLC

SFP module with 1 1000BaseLHX port with LC connector for 40 km transmission, 0 to 60°C

SFP-1GZXLC

SFP module with 1 1000BaseZX port with LC connector for 80 km transmission, 0 to 60°C

SFP-1GEZXLC

SFP module with 1 1000BaseEZX port with LC connector for 110 km transmission, 0 to 60°C

SFP-1G10ALC

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission, TX 1310 nm, RX 1550 nm, 0 to 60°C

SFP-1G10BLC

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission, TX 1550 nm, RX 1310 nm, 0 to 60°C

SFP-1G20ALC

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission, TX 1310 nm, RX 1550 nm, 0 to 60°C

SFP-1G20BLC

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission, TX 1550 nm, RX 1310 nm, 0 to 60°C

SFP-1G40ALC

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission, TX 1310 nm, RX 1550 nm, 0 to 60°C

SFP-1G40BLC

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission, TX 1550 nm, RX 1310 nm, 0 to 60°C

SFP-1GSXLC-T

SFP module with 1 1000BaseSX port with LC connector for 0.5 km transmission, -20 to 75°C

SFP-1GLXLC-T

SFP module with 1 1000BaseLX port with LC connector for 10 km transmission, -40 to 85°C

SFP-1GLHXLC-T

SFP module with 1 1000BaseLHX port with LC connector for 40 km transmission, -40 to 85°C

SFP-1GZXLC-T

SFP module with 1 1000BaseZX port with LC connector for 80 km transmission, -40 to 85°C

SFP-1G10ALC-T

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission, TX 1310 nm, RX 1550 nm, -40 to 85°C

SFP-1G10BLC-T

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission, TX 1550 nm, RX 1310 nm, -40 to 85°C

SFP-1G20ALC-T

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission, TX 1310 nm, RX 1550 nm, -40 to 85°C

SFP-1G20BLC-T

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission, TX 1550 nm, RX 1310 nm, -40 to 85°C

SFP-1G40ALC-T

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission, TX 1310 nm, RX 1550 nm, -40 to 85°C

SFP-1G40BLC-T

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission, TX 1550 nm, RX 1310 nm, -40 to 85°C