4-port RS-422/485 PC/104-Plus modules with 2 KV optical isolation protection |
 |
|
|
Features |
Specifications |
Ordering Information |
Features and Benefits
- 921.6 Kbps maximum baudrate for super fast data transmission
- On-chip H/W and S/W flow control
- Built-in 15 KV ESD protection
- Serial interface is DIP switch selectable
- Onboard Tx and Rx LED indicators for each port
- Windows CE 5.0 and Windows XP embedded operating systems supported
- Wide temperature model available for -40 to 85°C environments
Overview
The CB-134I PC/104-Plus module comes with 4 RS-232/422/485 ports, and can be used with PC/104-Plus CPU boards that accept the PC/104-Plus expansion interface. Optional DB9 and DB25 connection cables are available for connecting to serial devices, and the CB-134I's versatile driver support makes the module suitable for a wide range of applications. The CB-134Imodule can be used on the PC/104-Plus (PCI) bus, and provides a reliable, high performance solution for multiport serial communication.
|
| • Hardware | | Comm. Controller | MU860 (16C550C compatible) | | Bus | PC/104-Plus (PCI) bus | | Connectors for External Antenna | 40-pin box header | | DIP Switches | Serial interface |
| • Serial Interface | | Serial Standards | RS-422/485 | | Number of Ports | 4 | | Number of Boards | 4 per PC (max.) | | Serial Line Protection | ESD Protection: 15 KV on the board |
| • Performance | | Baudrate | 50 bps to 921.6 Kbps |
| • Serial Communication Parameters | | Data Bits | 5, 6, 7, 8 | | Stop Bits | 1, 1.5, 2 | | Parity | None, Even, Odd, Space, Mark | | I/O Address | Assigned by BIOS | | IRQ | Assigned by BIOS | | FIFO | 128 bytes |
| • Serial Signals | | RS-232 | TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND | | RS-422 | TxD+(B), TxD-(A), RxD+(B), RxD-(A), GND | | RS-485-4w | TxD+(B), TxD-(A), RxD+(B), RxD-(A), GND | | RS-485-2w | Data+(B), Data-(A), GND |
| • Driver Support | | Operating Systems | Windows (2000, XP/2003/Vista x86/x64), Windows CE 5.0, Windows XP Embedded, DOS, Linux 2.4/2.6, FreeBSD 4/5, QNX 6 |
| • Physical Characteristics | | Dimensions | 90 x 96 mm (3.54 x 3.78 in) |
| • Environmental Limits | | Operating Temperature | CB-134I: 0 to 55°C (32 to 131°F) CB-134I-T: -40 to 85°C (-40 to 185°F) | | Operating Humidity | 5 to 95% RH | | Storage Temperature | -40 to 85°C (-40 to 185°F) | | Regulatory Approvals | EN55022, EN55024, EN61000-3-2, EN61000-3-3, IEC61000-6-2, IEC61000-6-4, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8, IEC61000-4-11, FCC Part 15 Class A |
| • Power Requirements | | Power Consumption | 240 mA @ +5 V |
|

|
|