Location: Home >> Products >> Industrial Ethernet >> Industrial Ethernet Switches >> Managed Ethernet Switches >> EDS-510A Series

EDS-510A Series

7+3G-port Gigabit Managed Redundant Ethernet Switches

Datasheet
Manual
Drivers & Software
Larger image
 


Features
Specifications
Ordering Information

Features and Benefits

  • Turbo Ring (recovery time < 20 ms at full load) and RSTP/STP (IEEE 802.1w/D)
  • IGMP Snooping and GMRP for filtering multicast traffic
  • Port-based VLAN, IEEE 802.1Q VLAN and GVRP to ease network planning
  • QoS-IEEE 802.1p/1Q and TOS/DiffServ to increase determinism
  • Port Trunking for optimum bandwidth utilization
  • IEEE 802.1X, HTTPS, and SSH to enhance network security
  • SNMPv1/v2c/v3 for different levels of network management
  • RMON for efficient network monitoring and proactive capability
  • Bandwidth management prevents unpredictable network status
  • Lock port function for blocking unauthorized access based on MAC address
  • Port mirroring for online debugging
  • Automatic warning through e-mail and relay output
  • Digital inputs to integrate sensors and alarms with IP networks
 

Introduction

The EDS-510A Gigabit Managed Redundant Ethernet Switch is equipped with up to 3 Gigabit Ethernet ports, making it ideal for building a Gigabit Turbo Ring, but leaving a spare Gigabit port for uplink use. The Ethernet Redundant Turbo Ring (recovery time < 20 ms) and RSTP/STP (IEEE 802.1w/D) can increase system reliability and the availability of your network backbone. The EDS-510A Series is designed especially for communication demanding applications such as process control, shipbuilding, ITS, and DCS systems, which can benefit from a scalable backbone construction.


More info >>

•  Technology:
StandardsIEEE 802.3 for 10BaseT,
IEEE 802.3u for 100BaseT(X) and 100Base FX,
IEEE 802.3x for Flow Control,
IEEE 802.1D for Spanning Tree Protocol,
IEEE 802.1w for Rapid STP,
IEEE 802.1Q for VLAN Tagging,
IEEE 802.1p for Class of Service,
IEEE 802.1X for Authentication,
IEEE 802.3ad for Port Trunk with LACP,
IEEE 802.3ab for 1000Base(X),
IEEE 802.3z for 1000BaseSX/LX/LHX/ZX
ProtocolsIGMPv1/v2 device, GMRP, GVRP, SNMPv1/v2c/v3, DHCP Server/Client, DHCP Option 82, BootP, TFTP, SNTP, SMTP, RARP, RMON, HTTP, HTTPS, Telnet, SSH, Syslog
MIBMIB-II, Ethernet-Like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9
Flow ControlIEEE802.3x flow control, back pressure flow control


•  Switch Properties:
Priority Queues4
IGMP Groups256
Max. Number of Available VLANs64
VLAN ID RangeVID 1 to 4094


•  Interface:
RJ45 Ports10/100BaseT(X) or 10/100/1000BaseT(X) auto negotiation speed
Fiber Port(s)1000BaseSFP slot
ConsoleRS-232 (RJ45)
LED IndicatorsPWR1, PWR2, FAULT, 10/100M (TP port), 1000M (Gigabit port), MASTER, COUPLER
DIP SwitchesTurbo Ring, Master, Coupler, Reserve
Alarm ContactTwo relay outputs with current carrying capacity of 1A @ 24 VDC
Digital InputsTwo inputs with the same ground, but electrically isolated from the electronics
• +13 to +30V for state “1”
• -30 to +3V for state “0”
• Max. input current: 8 mA


•  Power Requirements:
Input Voltage24 VDC (12 to 45 VDC), redundant dual inputs
Input Current0.65A (EDS-510A-3GT)
0.44A (EDS-510A-1GT2SFP)
0.46A (EDS-510A-3SFP)
Overload Current ProtectionPresent
ConnectionTwo removable 6-pin terminal blocks
Reverse Polarity ProtectionPresent


•  Physical Characteristics:
EnclosureIP30 protection
HousingMetal case
Weight 1170 g
Dimensions80.2 x 135 x 105 mm (3.17 x 5.31 x 4.13 in)
InstallationDIN-Rail Mounting, Wall Mounting (optional kit)


•  Environmental Limits:
Operating Temperature0 to 60°C (32 to 140°F)

-40 to 75°C (-40 to 167°F) for T models
Storage Temperature-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity5 to 95% (non-condensing)


•  Agency Approvals:
EMIFCC Part 15, CISPR (EN55022) class A
EMSEN61000-4-2 (ESD), level 2
EN61000-4-3 (RS), level 3
EN61000-4-4 (EFT), level 2
EN61000-4-5 (Surge), level 3
EN61000-4-6 (CS), level 3
EN61000-4-8
EN61000-4-11
SafetyUL508, UL60950-1, CSA C22.2 No. 60950-1, EN60950-1
Hazardous LocationUL/cUL Class I, Division 2, Groups A, B, C, and D;
ATEX Class I, Zone 2, Ex nC IIC (Pending)
ShockIEC60068-2-27
FreefallIEC60068-2-32
VibrationIEC60068-2-6
MTBF (meantime between failures)204,000 hrs
Database: MIL-HDBK-217F, GB 25˚C
MaritimeDNV, GL


•  Warranty:
Warranty Period5 years
DetailsSee www.moxa.com/warranty



To request a quote, indicate which items you are interested in below and click "Get a Quote".
Standard Operating Temperature Models
 Model No. Description

EDS-510A-3GT

Industrial Gigabit Managed Redundant Ethernet Switch with 7 10/100BaseT(X) ports, 3 10/100/1000BaseT(X) ports

EDS-510A-3GT-T

Industrial Gigabit Managed Redundant Ethernet Switch with 7 10/100BaseT(X) ports, 3 10/100/1000BaseT(X) ports, -40 to 75°C

EDS-510A-1GT2SFP

Industrial Gigabit Managed Redundant Ethernet Switch with 7 10/100BaseT(X) ports, 1 10/100/1000BaseT(X) and 2 SFP (mini-GBIC) ports

EDS-510A-1GT2SFP-T

Industrial Gigabit Managed Redundant Ethernet Switch with 7 10/100BaseT(X) ports, 1 10/100/1000BaseT(X) and 2 SFP (mini-GBIC) ports, -40 to 75°C

EDS-510A-3SFP

Industrial Gigabit Managed Redundant Ethernet Switch with 7 10/100BaseT(X) ports, 3 SFP (mini-GBIC) ports

EDS-510A-3SFP-T

Industrial Gigabit Managed Redundant Ethernet Switch with 7 10/100BaseT(X) ports, 3 SFP (mini-GBIC) ports, -40 to 75°C

Gigabit Ethernet Modules, SFP-1G WDM-type (BiDi)
 Model No. Description

SFP-1G20BLC-T

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission, TX 1550 nm, RX 1310 nm, -40 to 85°C

SFP-1G40ALC

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission, TX 1550 nm, RX 1310 nm, 0 to 60°C

SFP-1G40ALC-T

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission, TX 1310 nm, RX 1550 nm, -40 to 85°C

SFP-1G10ALC

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission, TX 1310 nm, RX 1550 nm, 0 to 60°C

SFP-1G10ALC-T

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission, TX 1310 nm, RX 1550 nm, -40 to 75°C

SFP-1G10BLC

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission, TX 1550 nm, RX 1310 nm, 0 to 60°C

SFP-1G10BLC-T

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission, TX 1550 nm, RX 1310 nm, -40 to 85°C

SFP-1G20ALC

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission, TX 1310 nm, RX 1550 nm, 0 to 60°C

SFP-1G20ALC-T

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission, TX 1310 nm, RX 1550 nm, -40 to 85°C

SFP-1G20BLC

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission, TX 1550 nm, RX 1310 nm, 0 to 60°C

SFP-1G40BLC

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission, TX 1550 nm, RX 1310 nm, 0 to 60°C

SFP-1G40BLC-T

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission, TX 1550 nm, RX 1310 nm, -40 to 85°C

Gibabit Ethernet Modules, SFP-1G Series
 Model No. Description

SFP-1GSXLC

SFP module with 1 1000BaseSX port with LC connector for 0.5 km transmission, 0 to 60°C1000BaseSX, 0.5kmLC connector

SFP-1GLXLC

SFP module with 1 1000BaseLX port with LC connector for 10 km transmission, 0 to 60°C1000BaseLX, 10kmLC Connector

SFP-1GLHXLC

SFP module with 1 1000BaseLHX port with LC connector for 40 km transmission, 0 to 60°C 1000BaseLHX, 40 kmLC connector

SFP-1GZXLC

SFP module with 1 1000BaseZX port with LC connector for 80 km transmission, 0 to 60°C1000BaseZX, 80 kmLC connector

SFP-1GSXLC-T

SFP module with 1 1000BaseSX port with LC connector for 0.5 km transmission, -20 to 75°C1000BaseSX, 0.5kmLC connector-20 to 75°C

SFP-1GLXLC-T

SFP module with 1 1000BaseLX port with LC connector for 10 km transmission, -40 to 85°C1000BaseLX, 10kmLC connector-40 to 75°C

SFP-1GLHXLC-T

SFP module with 1 1000BaseLHX port with LC connector for 40 km transmission, -40 to 85°C1000BaseLHX, 40kmLC connector-40 to 75°C

SFP-1GZXLC-T

SFP module with 1 1000BaseZX port with LC connector for 80 km transmission, -40 to 85°C1000BaseZX, 80kmLC connector-40 to 75°C

DIN-Rail Power Supplies
 Model No. Description

DR-4524

45W/2A DIN-Rail 24 VDC power supply, 85 to 264 VAC input

DR-75-24

75W/3.2A DIN-Rail 24 VDC power supply, 85 to 264 VAC input

DR-120-24

120W/5A DIN-Rail 24 VDC power supply, 88 to 132 VAC/176 to 264 VAC input by switch

Backup Configurators
 Model No. Description

ABC-01

Automatic Backup Configurator through the RS-232 console port, 0 to 60°C

Mounting Kits
 Model No. Description

RK-4U

4U-high 19” rack mounting kit

WK-46

Wall Mounting Kit

SFP Modules
 Model No. Description

SFP-1G40ALC

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission, TX 1310 nm, RX 1550 nm, 0 to 60°C

SFP-1GLXLC

SFP module with 1 1000BaseLX port with LC connector for 10 km transmission, 0 to 60°C

SFP-1GSXLC

SFP module with 1 1000BaseSX port with LC connector for 0.5 km transmission, 0 to 60°C

SFP-1GLHXLC

SFP module with 1 1000BaseLHX port with LC connector for 40 km transmission, 0 to 60°C

SFP-1GZXLC

SFP module with 1 1000BaseZX port with LC connector for 80 km transmission, 0 to 60°C

SFP-1G10ALC

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission, TX 1310 nm, RX 1550 nm, 0 to 60°C

SFP-1G10BLC

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission, TX 1550 nm, RX 1310 nm, 0 to 60°C

SFP-1G20ALC

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission, TX 1310 nm, RX 1550 nm, 0 to 60°C

SFP-1G20BLC

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission, TX 1550 nm, RX 1310 nm, 0 to 60°C

SFP-1G40BLC

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission, TX 1550 nm, RX 1310 nm, 0 to 60°C

SFP-1GSXLC-T

SFP module with 1 1000BaseSX port with LC connector for 0.5 km transmission, -20 to 75°C

SFP-1GLXLC-T

SFP module with 1 1000BaseLX port with LC connector for 10 km transmission, -40 to 85°C

SFP-1GLHXLC-T

SFP module with 1 1000BaseLHX port with LC connector for 40 km transmission, -40 to 85°C

SFP-1GZXLC-T

SFP module with 1 1000BaseZX port with LC connector for 80 km transmission, -40 to 85°C

SFP-1G10ALC-T

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission, TX 1310 nm, RX 1550 nm, -40 to 85°C

SFP-1G10BLC-T

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission, TX 1550 nm, RX 1310 nm, -40 to 85°C

SFP-1G20ALC-T

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission, TX 1310 nm, RX 1550 nm, -40 to 85°C

SFP-1G20BLC-T

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission, TX 1550 nm, RX 1310 nm, -40 to 85°C

SFP-1G40ALC-T

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission, TX 1310 nm, RX 1550 nm, -40 to 85°C

SFP-1G40BLC-T

WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission, TX 1550 nm, RX 1310 nm, -40 to 85°C

Accessories - SNMP OPC Server Pro Software
 Model No. Description

EDS-SNMP OPC Server Pro

CD with EDS-SNMP OPC Server Pro Software and Manual