NPort IA5150/5250 Series

1 and 2-port serial device servers for industrial automation

 

Evaulation units available for online purchase
>> Buy now (USA only)

Features
Details
Specs
Ordering

Features and Benefits


  • Versatile socket operation modes, including TCP Server, TCP Client, UDP
  • Patented ADDC® (automatic data direction control) for 2-wire and 4-wire RS-485
  • Cascading Ethernet ports for easy wiring (applies only to RJ45 connectors)
  • Redundant DC power inputs
  • Warning by relay output and e-mail
  • 10/100BaseTX (RJ45) or 100BaseFX (single mode or multimode with SC connector)
  • IP30-rated housing

 

Overview


NPort® IA device servers provide easy and reliable serial-to-Ethernet connectivity for industrial automation applications. The device servers can connect any serial device to an Ethernet network, and to ensure compatibility with network software, they support a variety of port operation modes, including TCP Server, TCP Client, and UDP. The rock-solid reliability of the NPort® IA device servers makes them an ideal choice for establishing network access to RS-232/422/485 serial devices such as PLCs, sensors, meters, motors, drives, barcode readers, and operator displays. All models are housed in a compact, rugged housing that is DIN-rail mountable.




• LAN Interface
Number of Ports2
Speed10/100 Mbps, Auto MDI/MDIX
Connectors for External Antenna8-pin RJ45
Magnetic Isolation Protection1.5 KV built-in


• Optical Fiber Interface
Fiber Port(s)100 BasedFX, SC connector
DistanceMulti mode: 0 to 2 km, 1310 nm (62.5/125 µm, 500 MHz*km)
Single mode: 0 to 40 km, 1310 nm (9/125 µm, 3.5 PS/nm*km )
Min. TX Output-20 dBm (Multi mode), -5 dBm (Single mode)
Max. TX Output-14 dBm (Multi mode), 0 dBm (Single mode)
Sensitivity-34 to -30 dBm (Multi mode), -36 to -32 dBm (Single mode)


• Serial Interface
Serial StandardsRS-232/422/485
Number of PortsNPort® IA5150: 1
NPort® IA5250: 2
ConnectorsNPort® IA5150: 8-pin RJ45 for RS-232, Terminal Block for RS-422/485
NPort® IA5250: DB9 male
RS-485 Data Direction ControlADDC® (automatic data direction control)
ESD Protection15 KV for all signals
Isolation2 KV (NPort® IA5150I, NPort® 5150I-M-SC, NPort® 5150I-S-SC)


• Serial Communication Parameters
Data Bits5, 6, 7, 8
Stop Bits1, 1.5, 2
ParityNone, Even, Odd, Space, Mark
Flow ControlRTS/CTS (RS-232 only), XON/XOFF
Baudrate110 bps to 230.4 Kbps


• Serial Signals
RS-232NPort® IA5150: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
NPort® IA5250: TxD, RxD, RTS, CTS, GND
RS-422Tx+, Tx-, Rx+, Rx-, GND
RS-485-4wTx+, Tx-, Rx+, Rx-, GND
RS-485-2wData+, Data-, GND


• Software
Network ProtocolsICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet, Rtelnet, DNS, SNMP V1, HTTP, SMTP, SNTP
Driver SupportWindows Real COM driver (for Windows 95, 98, ME, NT, 2000, XP, 2003, Vista, XP x64, 2003 x64, Vista x64), Linux Real TTY driver, Fixed TTY driver (for SCO Unix, SCO OpenServer, UnixWare 7, UnixWare 2.1, SVR 4.2, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i)
Configuration OptionsWeb Console, Serial Console, Telnet Console, Windows Utility


• Physical Characteristics
EnclosureIP30 protection
Weight NPort® IA5150: 360 g
NPort® IA5250: 380 g
Dimensions29 x 89.2 x 118.5 mm (0.82 x 3.51 x 4.57 in)


• Environmental Limits
Operating TemperatureNPort® IA5150/5250: 0 to 55°C (32 to 131°F)
NPort® IA5150-T/5250-T: -40 to 75°C (-40 to 167°F)
Operating Humidity5 to 95% RH
Storage Temperature-40 to 85°C (-40 to 185°F)


• Power Requirements
Input Voltage12 to 48 VDC
Power ConsumptionNPort® IA5150: 360 mA @ 12V max.
NPort® IA5150I: 420 mA @ 12V max.
NPort® IA5250: 440 mA @ 12V max.
NPort® IA5150-S-SC: 470 mA @ 12V max.
NPort® IA5150I-S-SC: 490 mA @ 12V max.
NPort® IA5150-M-SC: 500 mA @ 12V max.
NPort® IA5150I-M-SC: 510 mA @ 12V max.


• Regulatory Approvals
SafetyUL60950 (E212360), UL 508, CSA C22.2 No. 60950, EN60950
EMIFCC Part 15, CISPR (EN55022) Class A
EMSEN61000-4-2 (ESD), Level 3
EN61000-4-3 (RS), Level 3
EN61000-4-4 (EFT), Level 4
EN61000-4-5 (Surge), Level 3
EN61000-4-6 (CS), Level 3
EN61000-4-8
EN61000-4-11
EN61000-4-12
ATEXClass I, Zone 2, EEx nC IIC (03CA24537)
Hazardous LocationUL/cUL Class I, Division 2,
Groups A, B, C and D (E238559)
ShockIEC60068-2-27
FreefallIEC60068-2-32
VibrationIEC60068-2-6
Dust-ProofIP30
MarineDNV


• Warranty
Warranty Period5 years
DetailsSee www.moxa.com/warranty



To request a quote, indicate which items you are interested in below and click "Get a Quote".
External Device Servers
 Model No. Description

NPort IA5150

1-port RS-232/422/485 serial device server, 2 x 10/100BaseT(X) (RJ45, Single IP)

NPort IA5150I

1-port RS-232/422/485 serial device server with 2 KV isolation, 2 x 10/100BaseT(X) (RJ45, Single IP)

NPort IA5250

2-port RS-232/422/485 serial device server, 2 x 10/100BaseT(X) (RJ45, Single IP)

NPort IA5150-S-SC

1-port RS-232/422/485 serial device server, 1-port 100BaseFx Single mode Fiber, SC connector

NPort IA5150I-S-SC

1-port RS-232/422/485 serial device server with 2 KV isolation, 1 100BaseFx Single mode Fiber, SC connector

NPort IA5150-M-SC

1-port RS-232/422/485 serial device server, 1-port 100BaseFx Multi mode Fiber, SC connector

NPort IA5150I-M-SC

1-port RS-232/422/485 serial device server with 2 KV isolation, 1-port 100BaseFx Multi mode Fiber, SC connector

DIN-Rail Power Supplies
 Model No. Description

DR-4524

45W/2A DIN-Rail 24 VDC power supply with universal 85 to 264 VAC input, -10 to 50°C operating temperature

DR-75-24

75W/3.2A DIN-Rail 24 VDC power supply with universal 85 to 264 VAC input, -10 to 60°C operating temperature

DR-120-24

120W/5A DIN-Rail 24 VDC power supply with universal 88 to 132 VAC or 176 to 264 VAC input by switch, -10 to 60°C operating temperature

SC to SC Fiber Cords
 Model No. Description

PA-MM(62.5)-2SC2SC-1M

1 meter

PA-MM(62.5)-2SC2SC-3M

3 meters

PA-MM(62.5)-2SC2SC-5M

5 meters

PA-MM(62.5)-2SC2SC-10M

10 meters

SC to ST Fiber Cords
 Model No. Description

PA-MM(62.5)-2SC2ST-1M

1 meter

PA-MM(62.5)-2SC2ST-3M

3 meters

PA-MM(62.5)-2SC2ST-5M

5 meters

PA-MM(62.5)-2SC2ST-10M

10 meters



Learn More

Cascading Ethernet Ports Make Wiring Easy (10/100BaseTX models only)

The NPort® IA5150 and IA5250 device servers each have two Ethernet ports that can be used as Ethernet switch ports. One port connects directly to the network or server, and the other port can be connected to another NPort® IA device server or another Ethernet device. The dual Ethernet ports help reduce wiring costs by eliminating the need to connect each device to a separate Ethernet switch.

 

Redundant Power Inputs

The NPort® IA5000 device servers have two power inputs that can be connected simultaneously to live DC power sources. If one power source fails, the other source takes over automatically. Redundant power inputs help assure non-stop operation of your device server.

 

Relay Output Warning and E-mail Alerts

The built-in relay output can be used to alert administrators of problems with the Ethernet links or power inputs, or when there is a change in the DCD or DSR serial signals. The web console indicates which Ethernet link or power input has failed, or which serial signal has changed. An e-mail warning can also be issued when an exception is detected. These functions are valuable tools that enable maintenance engineers to react promptly to emergency situations.

Optical Fiber for Ethernet Communication

The NPort® IA5000 series includes 100BaseFX fiber models that support transmission distances up to 2 km for multi-mode models, and up to 40 km for single-mode models. Optical fiber is well-suited for industrial applications because it is immune to electromagnetic noise and interference. For environments that experience high ground loop voltages, fiber provides the best isolation protection, and because there is no danger of sparking, optical fiber is safer than copper wire to use in hazardous environments.

 

Industrial-grade Certification

To ensure safe and reliable operation in industrial environments, the NPort® IA5000 device servers have obtained various industrial certifications, including an IP30 rating for mechanical protection, UL508 safety certification for industrial control equipment, and explosion-safe certifications for hazardous locations. Certifications include UL/cUL Class 1 Division 2 Groups A, B, C, D, and ATEX Class 1 Zone 2.

 

Appearance

 

 

Dimensions

 

Pin Assignment