Features and Benefits  

  • Five band UMTS/HSPA 800/850/AWS/1900/2100 MHz
  • Quad-band GSM/GPRS/EDGE 850/900/1800/1900 MHz
  • Cellular WAN and Ethernet WAN backup mechanism for a complete path redundancy
  • Primary and secondary power inputs for power source redundancy
  • GuaranLink and dual SIM redundancy for continuous cellular connections
  • Connect to 4 10/100BaseT(X) devices over an integrated VPN
  • Centralize private IP management with OnCell Central Manager
  • DIN rail and wall mountable housing
  • 2 digital inputs and 1 relay output (OnCell 5104-HSPA only)

Introduction 

The OnCell 5004/5104-HSPA series are high-performance industrial grade cellular routers that allow up to 4 Ethernet-based devices to simultaneously use a single cellular data account for primary or backup network connectivity to remote sites and devices. Both products provide the functionality of a cellular router, firewall, and switch in one device, and to ensure zero data loss and on-demand cellular communication, the OnCell 5004/5104-HSPA are integrated with the GuaranLink function. The difference between the OnCell 5004-HSPA and OnCell 5104-HSPA is that the OnCell 5104-HSPA comes with a built-in relay output that can be configured to indicate the priority of events when notifying or warning engineers in the field, and the two digital inputs allow you to connect basic I/O devices, such as sensors, to the cellular network. The OnCell 5004-HSPA can be placed on a desktop or wall-mounted, whereas the OnCell 5104-HSPA has an IA design and can be attached to a DIN-rail. Both products use 12 to 48 VDC power inputs with a screw-on design for greater reliability, and the Ethernet ports come with 1.5 KV magnetic isolation protection to keep your system safe from unexpected electrical discharges.

White Paper:

Critical Elements of Industrial-Grade Wireless Devices

 

Industrial operators using commercial-grade wireless devices for mission-critical wireless applications may be getting satisfactory wireless network service, but frequent maintenance and system downtime can add up to a high total cost of ownership. In this paper, we reveal many harmful effects commonly found in industrial environments that can quickly disable a commercial-grade wireless device, and discuss the types of protection an industrial-grade wireless device should provide to ensure continuous wireless network communication...more

 

Industrial Wireless Guidebook Download

Industrial WLAN and WWLAN Guide BookAdvantages of using wireless technologies include boosting data transmission speed, real-time data transmissions, remote equipment monitoring and alerts, flexible installation of remote equipment, and wide coverage areas. In addition, wireless technologies can penetrate areas where cables are unable to reach, saving wiring costs. By adopting wireless technologies, industrial applications are able to benefit from greater versatility.

However, the completeness of data, security of transmission, and reliability of the wireless network are constant concerns as wireless technologies rely completely on the emission of electromagnetic waves through the air. Drawing from over 20 years of experience, Moxa offers users the most reliable industrial networking solutions including Turbo Roaming™ for seamless wireless communication, as well as extended wireless transmission ranges of over 10 km. In addition, our complete selection of products for demanding industrial environments includes wide temperature (-40 to 75°C) models, IP67-rated protection from water and dust, and EN50155 certification for rail traffic applications.

We hope this guidebook will provide you with a more comprehensive understanding of industrial wireless technologies and serve as your most trusted guide to getting un-wired!  

Cellular Interface
Standards GSM/GPRS/EDGE/UMTS/HSPA
Band Options • Five-band UMTS/HSPA 800/850/AWS/1900/2100 MHz
• Quad-band GSM/GPRS/EDGE 850/900/1800/1900 MHz
HSPA Data Rate 14.4 Mbps DL, 5.76 Mbps UL
EDGE Multi-slot Class Class 12
EDGE Data Rate 237 Kbps DL, 237 Kbps UL
EDGE Terminal Device Class Class B
GPRS Multi-slot Class Class 12
GPRS Data Rate 85.6 Kbps DL, 85.6 Kbps UL
GPRS Terminal Device Class Class B
GPRS Coding Schemes CS1 to CS4
Tx Power UMTS/HSPA: 0.25 W
EDGE900: 0.5 W
EDGE1800: 0.4 W
GSM1800: 1 W
GSM900: 2 W
WAN Interface
Number of Ports 1
Ethernet 10/100 Mbps, RJ45 connector, Auto MDI/MDIX
LAN Interface
Number of Ports 4
Ethernet 10/100 Mbps, RJ45 connector, auto MDI/MDIX
SIM Interface
Number of SIMs 2
SIM Control 3 V
I/O Interface (OnCell 5104-HSPA)
Alarm Contact 1 relay output with current carrying capacity of 1 A @ 24 VDC
Digital Inputs 2 electrically isolated inputs
• +13 to +30 V for state “1” (On)
• +3 to -30 V for state “0” (Off)
Software
Network Protocols ARP, DDNS, DHCP/BOOTP, DNS Relay, HTTP, HTTPS, ICMP, IPSec, PPP, PPPoE, SMTP, SNTP, SSL, TCP/IP, Telnet, UDP
Routing/Firewall NAT, port forwarding, WAN IP filtering, static route
Authentication Local user-name and password
Cellular Connectivity GuaranLink
Management Software
Utilities OnCell Search Utility
Configuration and Management Options SNMP v1/v2c/v3, Web/Telnet/Serial Console, SSH, Remote SMS Control, Auto IP Report
Private IP Solution OnCell Central Manager
Physical Characteristics
Housing Aluminum, providing IP30 protection
Weight OnCell 5004-HSPA: 505±5 g
OnCell 5104-HSPA: 645±5 g
Dimensions OnCell 5004-HSPA: 158 x 103 x 34 mm (6.22 x 4.06 x 1.34 in)
OnCell 5104-HSPA: 135 x 50.8 x 103 mm (5.315 x 2.00 x 4.16 in)
Environmental Limits
Operating Temperature Standard Models: -30 to 55°C (-22 to 131°F)
Wide Temp. Models: -30 to 70°C (-22 to 158°F)
Storage Temperature -40 to 75°C (-40 to 167°F)
Ambient Relative Humidity 5 to 95% (30°C, non-condensing)
Power Requirements
Number of Power Inputs OnCell 5004-HSPA: 1 terminal block, 1 power jack
OnCell 5104-HSPA: 10-pin terminal block with dual power input
Input Voltage 12 to 48 VDC
Power Consumption OnCell 5004-HSPA: 12 to 48 VDC, 400 mA (idle), 900 mA (max.)
OnCell 5104-HSPA: 12 to 48 VDC, 450 mA (idle), 950 mA (max.)
Standards and Certifications
Safety UL 60950-1
EMC FCC Part 15 Subpart B Class A, EN 55022 Class A, EN 55024
Radio FCC Part 22H, FCC Part 24E, EN 301 489-1, EN 301 489-7, EN 301 489-24, EN 301 511, EN 301 908
Reliability
MTBF (mean time between failures) OnCell 5004-HSPA: 441,000 hrs
OnCell 5104-HSPA: 411,000 hrs
Warranty
Warranty Period 5 years
Details See www.moxa.com/warranty

To request a quote, indicate which items you are interested in below and click "Get a Quote".

Available Models

  Model No. Description
OnCell 5004-HSPA 4-port 10/100M Ethernet to GSM/GPRS/EDGE/UMTS/HSPA+ cellular router, -30 to 55°C operating temperature
OnCell 5104-HSPA 4-port 10/100M Ethernet to GSM/GPRS/EDGE/UMTS/HSPA+ cellular router, IA design, -30 to 55°C operating temperature
OnCell 5104-HSPA-T 4-port 10/100M Ethernet to GSM/GPRS/EDGE/UMTS/HSPA+ cellular router, IA design, -30 to 70°C operation temperature.

Optional Accessories

Cable
  Model No. Description
CRF-SMA(M)N(M)-300 N-type (male) to SMA (male), CFD200 cable, 3 m