ioLogik E2214

Active Ethernet I/O with 6 digital inputs and 6 relay outputs

 

Evaulation units available for online purchase
>> Buy now (USA only)

Features
Details
Specs
Ordering

Features and Benefits


  • Front-end intelligence that supports 24 Click&Go™ rules
  • Active Messaging with real-time stamp, including SMS, SNMP Trap with I/O status, TCP, and email
  • Supports SNMPv1/v2c/v3 protocol
  • I/O peer-to-peer function
  • Built-in web console
  • PC utility: Auto detection of installed modules
  • Windows/WinCE VB/VC.NET and Linux C APIs

Introduction

Moxa's ioLogik E2214 is a new type of active micro controller that can be used as an RTU (Remote Terminal Unit). Active Ethernet micro controllers are a kind of PC-based data acquisition and control device that use proactive, event-based reporting to control I/O devices. Unlike traditional RTUs, which are passive and must poll for data, Moxa's Active OPC Server makes seamless connection with SCADA systems a reality. In addition, SNMP is used for communicating with an NMS (Network Management System) for IT field users. The I/O status of an Active Ethernet micro controller can be reported and controlled automatically on-site based on user specified conditions. This report-by-exception approach, which is new to PC-based monitoring, requires far less bandwidth than traditional polling methods.



•  LAN:
Ethernet1 x 10/100 Mbps, RJ45
Protection1.5 KV magnetic isolation
ProtocolsModbus/TCP, TCP/IP, UDP, DHCP, Bootp, SNMP, HTTP, CGI, SNTP


•  Serial:
InterfaceRS-485-2w: Data+, Data-, GND
Serial Line Protection15 KV ESD for all signals


•  Serial Communication Parameters:
Baudrate1200 to 115200 bps
Data Bits8
Stop Bits1
ParityNone
Flow ControlNone
ProtocolsModbus/RTU


•  Digital Input:
Channels6, source/sink selectable
Sensor TypeNPN, PNP, and Dry contact
I/O ModeDI or Event Counter (up to 900 Hz)
Dry Contact• Logic 0: short to GND
• Logic 1: open
Wet Contact(For Source Type)
• Logic 0: 0 to 3 VDC
• Logic 1: 10 to 30 VDC
(For Sink Type)
• Logic 0: 10 to 30 VDC
• Logic 1: 0 to 3 VDC
Common Type3 points per COM
Isolation3K VDC or 2K Vrms
Counter/Frequency900 Hz, power off storage
Digital Filtering Time IntervalSoftware selectable
Over-voltage Protection36 VDC
Poweroff Counter MemorySupports poweroff counter storage function
Relay Counter SavingSupports relay counter storage function


•  Power Requirements:
Power Consumption282 mA typical @ 24 VDC
Power Input24 VDC nominal, 12 to 48 VDC


• Relay Output
Channels6 Form A (N.O.) relay outputs, 5A
Contact Rating5 A @ 30 VDC, 5 A @ 250 VAC, 5 A @ 110 VAC
Inductance Load2 A
Resistance Load5 A
Breakdown Voltage500 VAC
Relay On/Off Time10 ms, 5 ms (Max.)
Initial Insulation Resistance1G min. @ 500 VDC
Expected Life100,000 times (Typical)
Initial Contact Resistance30 milli-ohms (Max.)
Pulse Output0.3 Hz at rated load


•  Physical Characteristics:
Weight 225 g
Dimensions115 x 79 x 45.63 mm (4.53 x 3.11 x 1.80 in)
WiringI/O cable max. 14 AWG


•  Environmental Limits:
Operating Temperature-10 to 60°C (14 to 140°F)
Storage Temperature-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity5 to 95% (non-condensing)


•  Agency Approvals:
EMIFCC Part 15, CISPR (EN55022) class A
EMSIEC 61000-4, IEC 61000-6
SafetyUL508
ShockIEC 60068-2-27
FreefallIEC 60068-2-32
VibrationIEC 60068-2-6


•  Warranty:
Warranty Period2 years
DetailsSee www.moxa.com/warranty



To request a quote, indicate which items you are interested in below and click "Get a Quote".
Available Models
 Model No. Description

ioLogik E2214

Active Ethernet I/O with 6 digital inputs and 6 relay outputs

LCD Display module
 Model No. Description

LDP1602

LCD module with 16 x 2 text display and 5 buttons


Learn More

Dimensions (unit = mm)

Pin Assignment

I/O (left to right)