ioLogik E2214 New!
Active Ethernet I/O with 6 digital inputs and 6 relay outputs |
|
 |
Quickview |
 |
|
|
| |
 |
About Active Ethernet I/O |
 |
|
The Active Ethernet I/O is a new concept that introduces proactive,
condition-based reporting and control of I/O devices to PC-based data
acquisition and control. I/O status of an Active Ethernet I/O can be
automatically reported and controlled locally based on user specified
conditions. This report-by-exception approach, new to PC-based
I/O monitoring, requires far less bandwidth than traditional polling
methods. Critical sensor data can be obtained immediately instead
being confined by the use of to polling intervals. This makes network
communication between the host computer and Active Ethernet I/O
concise and efficient, and makes data transmission 20 times faster
compared with traditional SCADA systems (50 ms compared to 1 sec).
>> Learn more about Active Ethernet I/O
|
| |
 |
Introduction |
 |
|
| |
Remote Ethernet Relay Control
The ioLogik E2214 is a stand-alone Active Ethernet I/O product with 6
digital inputs and 6 relay outputs. The DIN-Rail mountable E2214 can
be connected to digital switches, alarm lights, buzzers, and warning sirens over Ethernet and IP-based networks. The ioLogik E2214
is designed to record the counts of the usage of the build-in relay
outputs. Even encountering the sudden power fail, the ioLogik E2214
is able to record the last counts into its internal storage before the
power is fully down.
More info >> |
|
Back to Top |
 |
Features |
 |
|
|
 |
6 DIs supporting PNP, NPN, and Dry contact |
|
 |
6 Form A relay output (Normal Open) |
|
 |
Relay specification: 5A/250 VAC, 5A/30 VDC |
 |
Instant event messaging by TCP/UDP/e-mail/SNMP trap |
 |
DI and Relay counter saving when power off |
 |
PC-based configuration utility and web console |
 |
Power On default relay status setting with sequence |
 |
Easy-to-use Click&Go™ Logic for local output control |
 |
Windows/WinCE VB/VC and Linux C API |
 |
I/O control over Modbus/TCP and SNMP protocol |
|
|
Back to Top |
 |
Specifications |
 |
|
|
LAN
|
|
|
|
|
|
| Modbus/TCP, TCP/IP, UDP, DHCP, Bootp, SNMP (MIB for
I/O and Network), HTTP, SNTP |
|
|
|
| |
Serial
|
|
| RS-485-2w: Data+, Data-, GND |
|
|
|
| 15 KV ESD for all signals |
|
|
|
| |
Serial Communication Parameters |
|
|
| |
Power Requirements |
|
|
|
| 24 VDC nominal, 12 to 48 VDC |
|
|
|
|
| 24 VDC nominal, up to 30 VDC |
|
|
|
|
| |
Physical Characteristics |
|
|
| |
Environmental Limits |
|
| -10 to 60°C (14 to 140°F) |
|
|
|
| -40 to 85°C (-40 to 185°F) |
|
| Ambient Relative Humidity |
|
| 5 to 95% (non-condensing) |
|
|
|
| |
Digital Input |
|
|
|
|
| NPN, PNP, and Dry contact |
|
|
|
| DI or Event Counter (up to 900 Hz) |
|
|
|
| Logic 0: short to GND, Logic 1: open |
|
|
|
Logic 0: 0 to 3 VDC,
Logic 1: 10 to 30 VDC |
|
|
|
|
|
|
|
|
| Digital Filtering Time Interval |
|
|
|
|
|
|
|
| |
Digital Output |
|
|
|
| 6 Form A (N.O.) relay outputs, 5A |
|
|
|
| 5A @ 30 VDC, 5A @ 250 VAC, 5A @ 110 VAC |
|
|
|
|
|
|
|
|
|
|
| Initial Insulation Resistance |
|
|
|
|
| Initial Contact Resistance |
|
|
|
| 20 operation times per minutes at rated load |
|
|
|
|
|
|
| |
Agency Approvals |
|
|
|
| FCC Part 15, CISPR (EN55022) class A |
|
|
|
|
|
|
|
|
|
|
|
|
| |
Warranty |
|
| 2 years (see www.moxa.com/warranty for details) |
|
|
|
| |
| |
 |
Ordering Information |
 |
|
| |
| ioLogik E2214 |
 |
|
| Active Ethernet I/O with 6 digital inputs and 6 relay outputs |
|
| LDP1602 |
 |
|
| LCD module with 16 x 2 text and 5 button |
|
|