As of June 15, 2022, this site no longer supports Internet Explorer. Please use another browser for the best experience on our site.
MOXA

Modbus TCP Gateways

Whether single or multiple serial ports, Moxa’s Modbus TCP gateway solutions convert data in networks between Modbus RTU/ASCII, Modbus TCP, DNP3, CANopen, J1939, PROFIBUS, BACnet/IP, IEC 101/104, IEC 61850, and EtherCAT making configuration, troubleshooting, and conversion quick and easy.

MGate MB3660-8-J-2AC
MGate MB3660 Series

Modbus gateway with dual LANs, dual AC power inputs, 8 RS-232/422/485 ports, RJ45 serial interface, 0 to 60°C operating temperature

Ethernet Interface
  • 10/100BaseT(X) Ports (RJ45 connector)

    • 2 IP addresses
      Auto MDI/MDI-X connection
Ethernet Software Features
  • Industrial Protocols

    • Modbus TCP Client (Master)
      Modbus TCP Server (Slave)
  • Configuration Options

    • Web Console (HTTP/HTTPS)
      Device Search Utility (DSU)
      MCC Tool
      Telnet Console
  • Management

    • ARP
      DHCP Client
      DNS
      HTTP
      HTTPS
      SMTP
      SNMP Trap
      SNMPv1/v2c/v3
      TCP/IP
      Telnet
      UDP
      NTP Client
      RADIUS
  • MIB

    • RFC1213, RFC1317
  • Time Management

    • NTP Client
Security Functions
  • Authentication

    • Local database
      RADIUS
  • Encryption

    • HTTPS
      AES-128
      AES-256
      SHA-256
  • Security Protocols

    • SNMPv3
      HTTPS (TLS 1.2)
Serial Interface
  • No. of Ports

    • 8
  • Connector

    • 8-pin RJ45
  • Serial Standards

    • RS-232/422/485 (software-selectable)
  • Baudrate

    • 50 bps to 921.6 kbps
  • Data Bits

    • 7, 8
  • Stop Bits

    • 1, 2
  • Parity

    • None
      Even
      Odd
      Space
      Mark
  • Flow Control

    • RTS/CTS
      DTR/DSR
      RTS Toggle (RS-232 only)
  • Console Port

    • RS-232 (TxD, RxD, GND), 8-pin RJ45 (115200, n, 8, 1)
  • Isolation

    • 2 kV (I models)
  • RS-485 Data Direction Control

    • ADDC (automatic data direction control)
  • Pull High/Low Resistor for RS-485

    • 1 kilo-ohm, 150 kilo-ohms
  • Terminator for RS-485

    • 120 ohms
Serial Signals
  • RS-232

    • TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
  • RS-422

    • Tx+, Tx-, Rx+, Rx-, GND
  • RS-485-2w

    • Data+, Data-, GND
  • RS-485-4w

    • Tx+, Tx-, Rx+, Rx-, GND
Serial Software Features
  • Industrial Protocols

    • Modbus RTU/ASCII Master
      Modbus RTU/ASCII Slave
  • Configuration Options

    • Serial Console
Modbus RTU/ASCII
  • Mode

    • Master, Slave
  • Functions Supported

    • 1, 2, 3, 4, 5, 6, 15, 16, 23
  • Max. No. of Commands

    • 256 per serial port
  • Memory Size

    • 65535 bytes
Modbus TCP
  • Mode

    • Client (Master), Server (Slave)
  • Max. No. of Client Connections

    • 256
  • Max. No. of Server Connections

    • 128
  • Functions Supported

    • 1, 2, 3, 4, 5, 6, 15, 16, 23
  • Max. No. of Commands

    • 256
  • Memory Size

    • 65535 bytes
Modbus (Transparent)
  • Max. No. of Client Connections

    • 256
  • Max. No. of Server Connections

    • 128
Power Parameters
  • Input Voltage

    • Redundant dual inputs
      100 to 240 VAC (47 to 63 Hz)
  • No. of Power Inputs

    • 2
  • Power Connector

    • Terminal block (for DC models)
  • Power Consumption

    • 235 mA @ 110 VAC
Relays
  • Contact Current Rating

    • Resistive load: 2 A @ 30 VDC
Physical Characteristics
  • Housing

    • Metal
  • IP Rating

    • IP30
  • Dimensions (with ears)

    • 480 x 45 x 198 mm (18.90 x 1.77 x 7.80 in)
  • Dimensions (without ears)

    • 440 x 45 x 198 mm (17.32 x 1.77 x 7.80 in)
  • Weight

    • 2600 g (5.73 lb)
Environmental Limits
  • Operating Temperature

    • 0 to 60°C (32 to 140°F)
  • Storage Temperature (package included)

    • -40 to 85°C (-40 to 185°F)
  • Ambient Relative Humidity

    • 5 to 95% (non-condensing)
Standards and Certifications
  • EMC

    • EN 55032/35
  • EMI

    • CISPR 32, FCC Part 15B Class A
  • EMS

    • IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
      IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
      IEC 61000-4-4 EFT: Power: 1 kV; Signal: 1 kV
      IEC 61000-4-5 Surge: Power: 2 kV; Signal: 1 kV
      IEC 61000-4-6 CS: 10 V
      IEC 61000-4-8 PFMF
  • Freefall

    • IEC 60068-2-31
  • Shock

    • IEC 60068-2-27
  • Vibration

    • IEC 60068-2-6
      IEC 60068-2-64
MTBF
  • Time

    • 616,505 hrs
  • Standards

    • Telcordia SR332
Warranty
Added To Bag
You have some items waiting in your bag; click here to finish your quote!
Feedback