TRC-190 Series

19-inch rackmount chassis media converter

moxa-trc-190-series-image-1-(1).jpg | Moxa
moxa-trc-190-series-image-2-(1).jpg | Moxa
moxa-trc-190-series-image-3-(1).jpg | Moxa

Features and Benefits

  • 19-inch chassis for rackmount use
  • 19 slots for high-density applications
  • Supports dual power inputs with redundancy
  • Fanless chassis design reduces servicing costs

Certifications

  • moxa-ul-listed-certification-logo-image.png | Moxa
  • moxa-ce-certification-logo-image.png | Moxa
  • moxa-fcc-certification-logo-image.png | Moxa
 
Contact Sales

Introduction

The TRC-190 rackmount chassis provides 19 slots for media converter modules from the CSM-200 Series of Ethernet-to-fiber modules and TCF-142-RM Series of serial-to-fiber modules. A TRC-190 chassis comes with one AC or DC power input, with an optional redundant power expansion AC or DC module available to enhance reliability. The PWR-190-AC and PWR-190-DC-48 power modules can be installed at the same time.

  • Input Voltage

    TRC-190-AC: 110 to 240 VAC
    TRC-190-DC-48: 36 to 53 VDC
    Redundant dual inputs

  • No. of Power Inputs

    2

  • Overload Current Protection

    Supported

  • Power Consumption

    TRC-190-AC: 0.9 A @ 110 VAC
    TRC-190-DC-48: 2.1 A @ 48 VDC

  • Dimensions

    440 x 260 x 88 mm (17.32 x 10.24 x 3.46 in)

  • Installation

    19-inch rack mounting

  • IP Rating

    IP30

  • Weight

    5200 g (11.4 lb)

  • Ambient Relative Humidity

    5 to 95% (non-condensing)

  • Operating Temperature

    0 to 60°C (32 to 140°F)

  • Storage Temperature (package included)

    -20 to 75°C (-4 to 167°F)

  • EMC

    EN 55032/24

  • EMI

    CISPR 32, FCC Part 15B Class A

  • EMS

    IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
    IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
    IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV
    IEC 61000-4-5 Surge: Power: 1 kV; Signal: 0.5 kV
    IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m
    IEC 61000-4-8 PFMF

  • Environmental Testing

    IEC 60068-2-1
    IEC 60068-2-2
    IEC 60068-2-3

  • Safety

    EN 60950-1, IEC 60950-1

  • Vibration

    IEC 60068-2-6

  • Time

    1,055,112 hrs

  • Standards

    Telcordia (Bellcore), GB

Support Documents

Name Type Version Release Date
Datasheet for TRC-190 Series
730.1 KB
Datasheet v1.0 2018-11-11 Nov 11, 2018
QIG for TRC-190 Series
815.7 KB
QIG v5.1 2017-06-06 Jun 06, 2017
3D CAD for TRC-190-AC
5.8 MB
3D CAD 2017-06-06 Jun 06, 2017
3D CAD for TRC-190-DC
5.8 MB
3D CAD 2017-06-06 Jun 06, 2017
2D CAD for TRC-190-AC
1.0 MB
2D CAD 2017-06-06 Jun 06, 2017
2D CAD for TRC-190-DC
348.1 KB
2D CAD 2017-06-06 Jun 06, 2017

Available Models (2)

Show Images
moxa-trc-190-ac-image.jpg | MoxaTRC-190-ACmoxa-trc-190-dc-48-image.jpg | MoxaTRC-190-DC-48
Input Voltage100-240 VAC (47-63 Hz)36-53 VDC
Add to QuoteView BagAdd to QuoteView Bag
Added To Bag

TRC-190 Series

TRC-190-AC

moxa-trc-190-ac-image.jpg | Moxa

Buy online from our distributors

TRC-190 Series

TRC-190-DC-48

moxa-trc-190-dc-48-image.jpg | Moxa