The PWR-100 Power Module Series are designed for Moxa’s EDS-4000/G4000 Series switches. The power modules allow supported switches to use 12/24/48 VDC or 110/220 VDC/VAC.
Save
The EDS-4000/G4000 Series device model name and power parameters are determined by the installed PWR-100 power module.PWR-100–LV: -LV/-LV-T modelsPWR-105-HV-I: -HV/-HV-T modelsPWR-101-LV-BP-I: -LVA/-LVA-T models (PoE support)PWR-103-LV-VB-I: -LVB/-LVB-T models (PoE support)For example:EDS-G4008-T + PWR-100-LV = EDS-G4008-LV-TEDS-G4008-T + PWR-105-HV-I = EDS-G4008-HVTIf you install a different power module, refer to the specifications of the corresponding model. For example, if you replace the power module of the EDS-G4008-LV-T with the PWR-105-HV-I, refer to the specifications of the EDS-G4008-HV-T.Power over Ethernet:Only the EDS-4008-4P-2GT-2GS(-T), EDS-4012-8P-4GS(-T), and EDS-G4012-8P-4QGS(-T) models support PoE. If a PoE-capable PWR-100 Series module (PWR-101-LV-BP-I, PWR-103-LV-VB-I) is installed into an EDS-4000/G4000 Series non-PoE model, PoE functionality will not be available.
2 removable 4-contact terminal block(s)
PWR-100-LV: 12/24/48 VDCPWR-105-HV-I: 110/220 VDC/VACPWR-101-LV-BP-I: 48 VDCPWR-103-LV-VB-I: 12/24/48 VDC
PWR-100-LV: 9.6 to 60 VDCPWR-105-HV-I: 88 to 300 VDC, 85 to 264 VACPWR-101-LV-BP-I: 44 to 57 VDC (> 52 VDC for PoE+ output recommended)PWR-103-LV-VB-I: 12 to 57 VDC (> 52 VDC for PoE+ output recommended)
PWR-100-LV: 12 to 48 VDC, 1.50 to 0.40 A or 24 VDC, 0.70 APWR-105-HV-I: 110 to 220 VAC, 50 to 60 Hz, 0.30 to 0.20 A or 110 to 220 VDC, 0.30 to 0.20 APWR-101-LV-BP-I: 48 VDC, 5.42 APWR-103-LV-VB-I: 12/48 VDC, 7.46/4.27 A or 24 VDC, 7.26 A
PWR-100-LV: Redundant dual inputsPWR-105-HV-I: Single inputPWR-101-LV-BP-I: Redundant dual inputsPWR-103-LV-VB-I: Redundant dual inputs
-LV models: Max. 0.8 A @ 48 VDC (0.1 to 1 ms)
Supported
PWR-100-LV: 103 x 98 x 26.6 mm (4.06 x 3.86 x 1.02 in)PWR-105-HV-I: 103 x 98 x 39.9 mm (4.06 x 3.86 x 1.57 in)PWR-101-LV-BP-I: 103 x 98 x 39.9 mm (4.06 x 3.86 x 1.57 in)PWR-103-LV-VB-I: 103 x 98 x 39.9 mm (4.06 x 3.86 x 1.57 in)
PWR-100-LV: 142 g (0.31 lb)PWR-105-HV-I: 215 g (0.47 lb)PWR-101-LV-BP-I: 176 g (0.39 lb)PWR-103-LV-VB-I: 244 g (0.54 lb)
The operating temperature is dependent on the EDS-4000/G4000 switch the module is installed in. Please refer to the respective EDS-4000/G4000 Series datasheet for more information.
-40 to 85°C (-40 to 185°F)
5 to 95% (non-condensing)
EN 62368-1 (LVD)
FCC Part 15 Subpart B Class A
EN 55032/35 EN 61000-6-2/-6-4
EN 61000-4-2 (ESD) Level 4EN 61000-4-3 (RS) Level 3EN 61000-4-4 (EFT) Level 4EN 61000-4-5 (Surge) Level 4EN 61000-4-6 (CS) Level 3EN 61000-4-8 Level 4
ISTA 1A
5 years
File Name: Firmware for Nport 6000 Series
Version: xx
SHA-512 Checksum: --checksum placeholder--
Copied to clipboard
This site uses cookies in order to improve your user experience and to provide content tailored specifically to your interests. By continuing to browse our site without changing your cookie settings (click the Learn More button for more information), or by clicking the OK button below, you hereby acknowledge and agree to our Privacy Policy and use of cookies.