As of June 15, 2022, this site no longer supports Internet Explorer. Please use another browser for the best experience on our site.
MOXA

PoE Switches

We provide a wide range of PoE/PoE+/PoE++ switches with up to 90 W output per port to deliver high-speed data transmission while powering high-power devices over long distances. With an industrial-grade design, our PoE switches provide surge protection of 4 kV per LAN port. Additionally, Smart PoE management features simplify PoE network deployment and maintenance.

PWR-101-LV-BP-I
PWR-100 Power Module Series

Power module for PoE models in the EDS-4000/G4000 Series with 48 VDC redundant dual inputs, power isolation, 44 to 57 VDC operating voltage (>52 VDC for PoE+ output recommended)

Power Parameters
  • Note

    • The EDS-4000/G4000 Series device model name and power parameters are determined by the installed PWR-100 power module.

      PWR-100–LV: -LV/-LV-T models
      PWR-105-HV-I: -HV/-HV-T models
      PWR-101-LV-BP-I: -LVA/-LVA-T models (PoE support)
      PWR-103-LV-VB-I: -LVB/-LVB-T models (PoE support)

      For example:
      EDS-G4008-T + PWR-100-LV = EDS-G4008-LV-T
      EDS-G4008-T + PWR-105-HV-I = EDS-G4008-HVT

      If you install a different power module, refer to the specifications of the corresponding model. For example, if you replace the power module of the EDS-G4008-LV-T with the PWR-105-HV-I, refer to the specifications of the EDS-G4008-HV-T.

      Power over Ethernet:
      Only the EDS-4008-4P-2GT-2GS(-T), EDS-4012-8P-4GS(-T), and EDS-G4012-8P-4QGS(-T) models support PoE. If a PoE-capable PWR-100 Series module (PWR-101-LV-BP-I, PWR-103-LV-VB-I) is installed into an EDS-4000/G4000 Series non-PoE model, PoE functionality will not be available.
  • Connection

    • 2 removable 4-contact terminal block(s)
  • Input Voltage

    • 48 VDC VDC
  • Operating Voltage

    • 44 to 57 VDC (> 52 VDC for PoE+ output recommended)
  • Input Current

    • 48 VDC, 5.42 A
  • No. of Power Inputs

    • Redundant dual inputs
  • Inrush Current (Max.)

    • Max. 0.8 A @ 48 VDC (0.1 to 1 ms)
  • Overload Current Protection

    • Supported
  • Reverse Polarity Protection

    • Supported
Physical Characteristics
  • Dimensions

    • 103 x 98 x 39.9 mm (4.06 x 3.86 x 1.57 in)
  • Weight

    • 176 g (0.39 lb)
Environmental Limits
  • Operating Temperature

    • The operating temperature is dependent on the EDS-4000/G4000 switch the module is installed in. Please refer to the respective EDS-4000/G4000 Series datasheet for more information.
  • Storage Temperature

    • -40 to 85°C (-40 to 185°F)
  • Ambient Relative Humidity

    • 5 to 95% (non-condensing)
Standards and Certifications
  • Safety

    • EN 62368-1 (LVD)
  • EMI

    • FCC Part 15 Subpart B Class A
  • EMC

    • EN 55032/35
      EN 61000-6-2/-6-4
  • EMS

    • EN 61000-4-2 (ESD) Level 4
      EN 61000-4-3 (RS) Level 3
      EN 61000-4-4 (EFT) Level 4
      EN 61000-4-5 (Surge) Level 4
      EN 61000-4-6 (CS) Level 3
      EN 61000-4-8 Level 4
  • Vibration

    • ISTA 1A
Warranty
  • Warranty Period

    • 5 years
Added To Bag
You have some items waiting in your bag; click here to finish your quote!
Feedback