As of June 15, 2022, this site no longer supports Internet Explorer. Please use another browser for the best experience on our site.

TN-4100 Series

EN 50155 4-port ETBN repeaters

moxa-tn-4100-series-image-(1).jpg | Moxa
moxa-tn-4100-series-image-1-(1).jpg | Moxa
moxa-tn-4100-series-image-2-(1).jpg | Moxa

Features and Benefits

  • Dual isolated IEC 61375 ETBN repeaters in one compact form factor
  • 4 DIP switch-configurable ports with full TTDP/TRDP protocol transparency
  • IEC 61076-010 compliant inner-locking M12 push-pull ports, relay alarms, and hardware bypass
  • Isolated power module with dual 24 to 110 VDC inputs
  • Complies with all EN 50155 mandatory test items This product is suitable for rolling stock railway applications, as defined by the EN 50155 standard. For a more detailed statement, click here: www.moxa.com/doc/specs/EN_50155_Compliance.pdf
  • -40 to 70°C wide-temperature design

Certifications

  • moxa-en50155-certification-logo-image.png | Moxa
  • moxa-en50121-4-certification-logo-image.png | Moxa
  • moxa-ce-certification-logo-image.png | Moxa
  • moxa-fcc-certification-logo-image.png | Moxa
 
Contact Sales

Introduction

The ToughNet TN-4100 Series M12 ETBN repeaters are EN 50155-certified devices designed for harsh industrial and railway rolling stock environments. By regenerating both Ethernet frame data and electrical signal characteristics, the TN-4100 Series enables Ethernet segment extension beyond the standard 100-meter limit. In accordance with IEC 61375-2-1, these repeaters are installed between Ethernet train backbone nodes (ETBNs) to provide transparent link extension, ensuring stable communication across extended vehicle consist lengths, such as articulated or multi-car trains.

The TN-4100 Series combines two isolated IEC 61375 ETBN repeaters into a single compact housing to save installation space and simplify system deployment. Equipped with four M12 ports featuring IEC 61076-010 inner-locking push-pull connectors and DIP switch configuration, these repeaters ensure tight, robust connections and offer complete protocol transparency for train communications, including TTDP and TRDP.

All TN-4100 Series models support an extended operating temperature range of -40 to 70°C and fully comply with the mandatory requirements of the EN 50155 standard, including temperature, power input range, surge, ESD, and vibration resistance. Additionally, the TN-4100 Series features a single isolated power module with dual 24 to 110 VDC power inputs and integrated relay alarm outputs to ensure high availability, scalable network design, and uninterrupted on-board operations.

  • 100BaseT(X) Ports (M12 D-coded 4-pin female connector with bypass relay)

    4

  • Standards

    IEEE 802.3u for 100BaseT(X)

  • LED Indicators

    PWR, Ethernet ports, MDI/MDIX

  • Input Current

    0.25 A @ 24 VDC

  • Input Voltage

    24/36/48/72/96/110 VDC

  • No. of Power Inputs

    2

  • Operating Voltage

    16.8 to 137.5 VDC

  • Power Connector

    M12 K-coded 5-pin male connector

  • Overload Current Protection

    Supported

  • Reverse Polarity Protection

    Supported

  • Housing

    Metal

  • IP Rating

    IP40

  • Dimensions

    115 x 159.8 x 70 mm (4.53 x 6.29 x 2.76 in)

  • Weight

    792 g (1.75 lb)

  • Installation

    Wall mounting

  • Protection

    PCB conformal coating

  • Operating Temperature

    -40 to 70°C (-40 to 158°F)

  • Storage Temperature (package included)

    -40 to 85°C (-40 to 185°F)

  • Ambient Relative Humidity

    5 to 95% (non-condensing)

  • Altitude

    3000 m

  • EMC

    EN 55032/35

  • EMI

    CISPR 32, FCC Part 15B Class A

  • EMS

    IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
    IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
    IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
    IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
    IEC 61000-4-6 CS: 10 V
    IEC 61000-4-8 PFMF

  • Radio Frequency

    FCC

  • Environmental Testing

    IEC 60068-2-1, EN 50155
    IEC 60068-2-14, EN 50155
    IEC 60068-2-2, EN 50155
    IEC 60068-2-30, EN 50155
    IEC 60068-2-78

  • Railway

    EN 50121-4
    EN 50155
    IEC 60571

  • Railway Fire Protection

    EN 45545-2

  • Safety

    IEC 62368-1
    UL 62368-1
    EN 62368-1

  • Salt Spray Test

    EN 50155

  • Shock

    IEC 60068-2-27, IEC 61373, EN 50155

  • Vibration

    IEC 60068-2-64, IEC 61373, EN 50155

  • Package Vibration Test

    ISTA 1A

  • Package Drop Test

    ISTA 1A

  • Green Product

    RoHS, CRoHS, WEEE

  • Time

    3,270,455 hrs

  • Standards

    Telcordia SR332 Issue 4

Support Documents

Name Type Version Release Date
Datasheet for TN-4100 Series
6.9 MB
Datasheet v1.0 Sep 18, 2026 Sep 18, 2026

Available Models (1)

Show Images
TN-4104-4TXBP-WV-CT-T
100BaseT(X) Ports, M12 D-coded 4 pin Female Connector With Bypass Relay4
100/1000BaseT(X) Ports, M12 X-coded 8 pin Female Connector With Bypass Relay–
Conformal Coating✓
Add to QuoteView Bag

product image

Buy online from distributors

Added To Bag
You have some items waiting in your bag; click here to finish your quote!
Feedback