As of June 15, 2022, this site no longer supports Internet Explorer. Please use another browser for the best experience on our site.
MOXA

Intelligent Integrated Node

Intelligent Integrated Node (IIN) is an advanced RTU designed for industrial applications in harsh environments. IIN delivers industrial-grade reliability and flexibility with support for multiple IT/OT protocols, enabling seamless integration with SCADA, plant monitoring, and cloud systems. IIN provides the flexibility to build an RTU based on your application needs with expansion capability to ramp up the I/O capacity as needed, making it easy to deploy and maintain.

RK-4U-65M
ioPAC 6500 Series

Rackmount kit for ioPAC 6500 series, 4U

System Performance
  • Max. No. of Control Units

    • 1
  • Max. No. of Expansion Units

    • 4
  • Max. No. of Power Backplanes Per Unit

    • Control and expansion units:
      1 (1/ 2 slots)
  • Max. No. of CPU Backplanes Per Unit

    • Control unit:
      1 (1/2 slots)
  • Max. No. of Communication Backplanes Per Unit

    • Control unit:
      1 (1/2 slots)
  • Max. No. of I/O Backplanes Per Unit

    • Control and expansion units:
      2 (2/4 slots)
  • Max. No. of Expansion Backplanes Per Unit

    • Control and expansion units:
      1 (1/2 slots)
Physical Characteristics
  • Housing

    • Plastic
  • Installation

    • DIN-rail mounting
      Rack mounting (with optional kit)
Environmental Limits
  • Operating Temperature

    • -40 to 75°C (-40 to 167°F)
      Note: Proper airflow is required in an environment with temperature > 65°C
  • Storage Temperature (package included)

    • -40 to 85°C (-40 to 185°F)
  • Ambient Relative Humidity

    • 5 to 95% (non-condensing)
  • Altitude

    • 2000 m
Standards and Certifications
  • EMC

    • EN 55032/35
      EN 61000-6-2/-6-4
  • EMI

    • CISPR 32, FCC Part 15B Class A
  • EMS

    • IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
      IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
      IEC 61000-4-4 EFT: Power: (DC) 1 kV; Signal: 1 kV
      IEC 61000-4-5 Surge: Power: (DC) 0.5 kV L-N, 1 kV L/N-PE; Signal: 1 kV; IO: 0.5 kV
      IEC 61000-4-6 CS: Power: 10 V; Signal: 10 Vrms
      IEC 61000-4-8 PFMF: 30 A/m
  • Safety

    • UL 61010-1
      UL 61010-2-201
  • Shock

    • IEC 60068-2-27
      Half sine wave; acceleration: 15 g; time: 11 ms
  • Vibration

    • IEC 60068-2-6
      DIN-rail mounted:
      7 mm peak-peak (p-p) (2 to 8.42 Hz), 1 g (8.42 to 150 Hz)
      Rack mounted (with optional kit):
      7 mm peak-peak (p-p) (2 to 8.42 Hz), 0.5 g (8.42 to 150 Hz)
  • Package Vibration Test

    • ISTA 1A
  • Package Drop Test

    • ISTA 1A
MTBF
  • Standards

    • Telcordia Standard SR-332
  • Time

    • See the datasheets for the modules for details.
Warranty
Added To Bag
You have some items waiting in your bag; click here to finish your quote!
Feedback