Features and Benefits

  • Protocol conversion between Modbus, PROFINET, EtherNet/IP, and PROFIBUS
  • Supports PROFIBUS DP V0 slave
  • Supports Modbus RTU/ASCII/TCP master/client and slave/server
  • Supports EtherNet/IP Adapter
  • Supports PROFINET IO device
  • Effortless configuration via web-based wizard
  • Built-in Ethernet cascading for easy wiring
  • Embedded traffic monitoring/diagnostic information for easy troubleshooting
  • Status monitoring and fault protection for easy maintenance
  • microSD card for configuration backup/duplication and event logs
  • Supports redundant dual DC power inputs and 1 relay output
  • Serial port with 2 kV isolation protection
  • -40 to 75°C wide operating temperature models available
  • Security features based on IEC 62443

Certifications

  • moxa-atex-certification-logo-image.png | Moxa
  • moxa-iecex-certification-logo-image.png | Moxa
  • moxa-ul-listed-certification-logo-image.png | Moxa
  • moxa-ce-certification-logo-image.png | Moxa
 
Contact Sales

Introduction

MGate 5111 industrial Ethernet gateways convert data between the Modbus RTU/ASCII/TCP, EtherNet/IP, PROFINET, and PROFIBUS protocols. All models are protected by a rugged metal housing, are DIN-rail mountable, and offer built-in serial isolation.

Modbus is one of the most widely used industrial communication protocols, and EtherNet/IP, PROFINET, and PROFIBUS are commonly used in factory automation and process automation. The MGate 5111 supports both Modbus RTU/ASCII/TCP master and slave modes, so that you can easily connect your Modbus device to PROFIBUS PLCs or DCSs, such as Siemens PLCs.

For system integration, the MGate 5111 can connect to EtherNet/IP PLC/SCADA systems, such as Rockwell Automation PLCs, to PROFIBUS PLC/DCS systems, or between a new Siemens PLC system that supports PROFINET to an existing PROFIBUS system. The MGate 5111 gateways are designed for easy configuration and quick maintenance. A handy web console can be used to implement remote maintenance tasks, and the configuration wizard UI lets you quickly set up your gateway. A comprehensive collection of troubleshooting tools reduce configuration time and system downtime. The rugged design is suitable for industrial applications, such as factory automation, power, oil and gas, water and wastewater, and other process automation industries.

Easy Configuration

The MGate 5111 Series has a user-friendly interface that lets you quickly set up protocol conversion routines for most applications, doing away with what were often time-consuming tasks in which users had to implement detailed parameter configurations one by one. With Quick Setup, you can easily access protocol conversion modes and finish the configuration in a few steps.

The MGate 5111 supports a web console and Telnet console for remote maintenance. Encryption communication functions, including HTTPS and SSH, are supported to provide better network security. In addition, system monitoring functions are provided to record network connections and system log events.

A Variety of Maintenance Functions

The MGate 5111 supports Protocol Diagnose and Traffic Monitor for easy troubleshooting, especially during the installation stage. Communication issues caused by incorrect software parameters, such as slave IDs and register addresses, or incorrect command configurations, can be fished out with Protocol Diagnose and Traffic Monitoring, which let you capture and check data to easily identify root causes.

MGate 5111 gateways also support status monitoring and fault protection functions. The status monitoring function notifies a PLC/DCS/SCADA system when a Modbus device gets disconnected or does not respond, in which case the process PLC/DCS gets the status of each end device and then issues alarms to notify operators. When a PROFIBUS cable gets disconnected, the fault protection function executes actions on end devices identified by a predefined value set by the user.

  • 10/100BaseT(X) Ports (RJ45 connector)

    2
    Auto MDI/MDI-X connection

  • Magnetic Isolation Protection

    1.5 kV (built-in)

  • Industrial Protocols

    EtherNet/IP Adapter (Slave), Modbus TCP Client (Master), Modbus TCP Server (Slave), PROFINET IO Device (Slave)

  • Configuration Options

    Device Search Utility (DSU), Web Console, Telnet Console

  • Management

    ARP, DHCP Client, DNS, HTTP, HTTPS, SMTP, SNMP Trap, SNMPv1/v2c/v3, TCP/IP, Telnet, SSH, UDP

  • MIB

    MIB-II

  • Time Management

    NTP Client

  • Console Port

    RS-232 (TxD, RxD, GND), 8-pin RJ45 (115200, n, 8, 1)

  • No. of Ports

    1

  • Connector

    DB9 male

  • Serial Standards

    RS-232/422/485

  • Baudrate

    50 bps to 921.6 kbps

  • Data Bits

    7, 8

  • Parity

    None, Even, Odd, Space, Mark

  • Stop Bits

    1, 2

  • Flow Control

    RTS Toggle (RS-232 only), RTS/CTS

  • RS-485 Data Direction Control

    ADDC® (automatic data direction control)

  • Pull High/Low Resistor for RS-485

    1 kilo-ohm, 150 kilo-ohms

  • Terminator for RS-485

    120 ohms

  • Isolation

    2 kV (built-in)

  • RS-232

    TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND

  • RS-422

    Tx+, Tx-, Rx+, Rx-, GND

  • RS-485-2w

    Data+, Data-, GND

  • RS-485-4w

    Tx+, Tx-, Rx+, Rx-, GND

  • Configuration Options

    Serial Console

  • Industrial Protocols

    Modbus RTU/ASCII Master, Modbus RTU/ASCII Slave

  • Mode

    Master, Slave

  • Functions Supported

    1, 2, 3, 4, 5, 6, 15, 16, 23

  • Max. No. of Commands

    128

  • Input Data Size

    2048 bytes

  • Output Data Size

    2048 bytes

  • Mode

    Client, Server

  • Functions Supported

    1, 2, 3, 4, 5, 6, 15, 16, 23

  • Max. No. of Client Connections

    16

  • Max. No. of Server Connections

    32

  • Max. No. of Commands

    128

  • Input Data Size

    2048 bytes

  • Output Data Size

    2048 bytes

  • Industrial Protocols

    PROFIBUS DP

  • No. of Ports

    1

  • Connector

    DB9 female

  • Baudrate

    9600 bps to 12 Mbps

  • Isolation

    2 kV (built-in)

  • Signals

    PROFIBUS D+, PROFIBUS D-, RTS, Signal Common, 5V

  • Rotary Switch

    PROFIBUS addresses 0-99 (addresses 100-125 supported through software configuration)

  • Mode

    DP-V0 Slave

  • Max. No. of Master Connections

    1

  • Max. No. of PROFIBUS I/O Modules

    24

  • Input Data Size

    244 bytes

  • Output Data Size

    244 bytes

  • Mode

    IO Device (Slave)

  • Max. No. of IO Controller Connections

    1 (for read/write)

  • Input Data Size

    512 bytes

  • Output Data Size

    512 bytes

  • Mode

    Adapter

  • CIP Objects Supported

    Identity, Message Router, Assembly, Connection Manager, TCP/IP interface, Ethernet link, Port

  • Max. No. of Scanner Connections

    1 (for read-only), 1 (for read/write)

  • Input Data Size

    496 bytes

  • Output Data Size

    496 bytes

  • microSD Slot

    Up to 32 GB (SD 2.0 compatible)

  • Input Voltage

    12 to 48 VDC

  • Input Current

    416 mA @ 12 VDC

  • Power Connector

    Spring-type Euroblock terminal

  • Contact Current Rating

    Resistive load: 2 A @ 30 VDC

  • Housing

    Metal

  • IP Rating

    IP30

  • Dimensions

    45.8 x 105 x 134 mm (1.8 x 4.13 x 5.28 in)

  • Weight

    589 g (1.30 lb)

  • Operating Temperature

    MGate 5111: 0 to 60°C (32 to 140°F)
    MGate 5111-T: -40 to 75°C (-40 to 167°F)

  • Storage Temperature (package included)

    -40 to 85°C (-40 to 185°F)

  • Ambient Relative Humidity

    5 to 95% (non-condensing)

  • Safety

    EN 60950-1, UL 61010-2-201

  • EMC

    EN 61000-6-2/-6-4

  • EMI

    CISPR 32, FCC Part 15B Class A

  • EMS

    IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
    IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
    IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
    IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
    IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m
    IEC 61000-4-8 PFMF

  • Hazardous Locations

    ATEX, Class I Division 2, IECEx

  • Freefall

    IEC 60068-2-32

  • Shock

    IEC 60068-2-27

  • Vibration

    IEC 60068-2-6, IEC 60068-2-64

  • Time

    718,131 hrs

  • Standards

    Telcordia SR332

Software, Firmware, and Drivers

FILTER

Name Type Version Operating System Release Date
MXconfig Plugin for MGate Series
404.4 KB
Software Package v1.5
  • Windows 10
  • Windows 7
  • Windows 8
  • Windows Server 2008
  • Windows Server 2012
  • Windows Server 2012 R2
2018-12-24 Dec 24, 2018 Release notes
MXview Plugin for MGate Series
2.8 MB
Software Package v2.5
  • Windows 10
  • Windows 7
  • Windows 8
  • Windows Server 2008
  • Windows Server 2012
  • Windows Server 2012 R2
2018-12-24 Dec 24, 2018 Release notes
Software Package for MGate 5111 Series (EtherNet/IP Adapter EDS)
11.4 KB
Software Package v2.0
2018-04-11 Apr 11, 2018 Release notes
Firmware for MGate 5111 Series
7.9 MB
Firmware v1.1
2018-03-02 Mar 02, 2018 Release notes
MIB file for MGate 5111 Series
15.2 KB
Software Package v1.0
2018-01-19 Jan 19, 2018 Release notes
GSD file for MGate 5111 Series
4.8 KB
Software Package v1.0
2018-01-19 Jan 19, 2018 Release notes
GSDML file for MGate 5111 Series
25.4 KB
Software Package v1.0
2018-01-19 Jan 19, 2018 Release notes
DSU Utility
1.1 MB
Utility v2.2
  • Windows 95
  • Windows Server 2012 R2
  • Windows 7
  • Windows NT
  • Windows XP
  • Windows Server 2008 R2
  • Windows 98
  • Windows 2000
  • Windows Server 2012
  • Windows 10
  • Windows Vista
  • Windows 8
  • Windows Server 2016
  • Windows Server 2008
  • Windows Server 2003
  • Windows 8.1
  • Windows ME
2018-01-19 Jan 19, 2018 Release notes

Support Documents

Name Type Version Release Date
Datasheet for MGate 5111 Series
722.1 KB
Datasheet v1.0 2018-11-11 Nov 11, 2018
Tech Note for MGate 5111 Series (How to Configure MGate 5111 with TIA Portal for Siemens PLC)
1.9 MB
Tech Note v1.0 2017-12-29 Dec 29, 2017
QIG for MGate 5111 Series
1.7 MB
QIG v1.0 2017-12-22 Dec 22, 2017
Manual for MGate 5111 Series
6.6 MB
Manual v1.0 2017-12-22 Dec 22, 2017
3D CAD for Mgate 5111
4.5 MB
3D CAD 2017-12-22 Dec 22, 2017
2D CAD for Mgate 5111
133.0 KB
2D CAD 2017-12-22 Dec 22, 2017

Available Models (2)

Show Images
moxa-mgate-5111-image.jpg | MoxaMGate 5111moxa-mgate-5111-t-image.jpg | MoxaMGate 5111-T
Operating Temp.0 to 60°C-40 to 75°C
Add to QuoteView BagAdd to QuoteView Bag
Added To Bag

MGate 5111 Series

MGate 5111

moxa-mgate-5111-image.jpg | Moxa

Buy online from our distributors

MGate 5111 Series

MGate 5111-T

moxa-mgate-5111-t-image.jpg | Moxa

Buy online from our distributors