As of June 15, 2022, this site no longer supports Internet Explorer. Please use another browser for the best experience on our site.

MGate 5111 Series

1-port Modbus/PROFINET/EtherNet/IP to PROFIBUS slave gateways

moxa-mgate-5111-series-image-1-(1).jpg | Moxa
moxa-mgate-5111-series-image-2-(1).jpg | Moxa
moxa-mgate-5111-series-image-3-(1).jpg | Moxa

Features and Benefits

  • Converts Modbus, PROFINET, or EtherNet/IP to PROFIBUS
  • Supports PROFIBUS DP V0 slave
  • Supports Modbus RTU/ASCII/TCP master/client and slave/server
  • Supports EtherNet/IP Adapter
  • Supports PROFINET IO device
  • Effortless configuration via web-based wizard
  • Built-in Ethernet cascading for easy wiring
  • Embedded traffic monitoring/diagnostic information for easy troubleshooting
  • Status monitoring and fault protection for easy maintenance
  • microSD card for configuration backup/duplication and event logs
  • Supports redundant dual DC power inputs and 1 relay output
  • Serial port with 2 kV isolation protection
  • -40 to 75°C wide operating temperature models available
  • Security features based on IEC 62443

Certifications

  • moxa-atex-certification-logo-image.png | Moxa
  • moxa-iecex-certification-logo-image.png | Moxa
  • moxa-ul-listed-certification-logo-image.png | Moxa
  • moxa-ce-certification-logo-image.png | Moxa
 
Contact Sales

Introduction

MGate 5111 industrial Ethernet gateways convert data from Modbus RTU/ASCII/TCP, EtherNet/IP, or PROFINET to PROFIBUS protocols. All models are protected by a rugged metal housing, are DIN-rail mountable, and offer built-in serial isolation.

Modbus is one of the most widely used industrial communication protocols, and EtherNet/IP, PROFINET, and PROFIBUS are commonly used in factory automation and process automation. The MGate 5111 supports both Modbus RTU/ASCII/TCP master and slave modes, so that you can easily connect your Modbus device to PROFIBUS PLCs or DCSs, such as Siemens PLCs.

For system integration, the MGate 5111 can connect to EtherNet/IP PLC/SCADA systems, such as Rockwell Automation PLCs, to PROFIBUS PLC/DCS systems, or between a new Siemens PLC system that supports PROFINET to an existing PROFIBUS system. The MGate 5111 gateways are designed for easy configuration and quick maintenance. A handy web console can be used to implement remote maintenance tasks, and the configuration wizard UI lets you quickly set up your gateway. A comprehensive collection of troubleshooting tools reduce configuration time and system downtime. The rugged design is suitable for industrial applications, such as factory automation, power, oil and gas, water and wastewater, and other process automation industries.

Easy Configuration

The MGate 5111 Series has a user-friendly interface that lets you quickly set up protocol conversion routines for most applications, doing away with what were often time-consuming tasks in which users had to implement detailed parameter configurations one by one. With Quick Setup, you can easily access protocol conversion modes and finish the configuration in a few steps.

The MGate 5111 supports a web console and Telnet console for remote maintenance. Encryption communication functions, including HTTPS and SSH, are supported to provide better network security. In addition, system monitoring functions are provided to record network connections and system log events.

A Variety of Maintenance Functions

The MGate 5111 supports Protocol Diagnose and Traffic Monitor for easy troubleshooting, especially during the installation stage. Communication issues caused by incorrect software parameters, such as slave IDs and register addresses, or incorrect command configurations, can be fished out with Protocol Diagnose and Traffic Monitoring, which let you capture and check data to easily identify root causes.

MGate 5111 gateways also support status monitoring and fault protection functions. The status monitoring function notifies a PLC/DCS/SCADA system when a Modbus device gets disconnected or does not respond, in which case the process PLC/DCS gets the status of each end device and then issues alarms to notify operators. When a PROFIBUS cable gets disconnected, the fault protection function executes actions on end devices identified by a predefined value set by the user.

  • 10/100BaseT(X) Ports (RJ45 connector)

    2
    Auto MDI/MDI-X connection

  • Magnetic Isolation Protection

    1.5 kV (built-in)

  • Industrial Protocols

    Modbus TCP Client (Master)
    Modbus TCP Server (Slave)
    PROFINET IO Device
    EtherNet/IP Adapter

  • Configuration Options

    Web Console (HTTP/HTTPS)
    Device Search Utility (DSU)
    Telnet Console

  • Management

    ARP
    DHCP Client
    DNS
    HTTP
    HTTPS
    SMTP
    SNMP Trap
    SNMPv1/v2c/v3
    TCP/IP
    Telnet
    SSH
    UDP
    NTP Client

  • MIB

    RFC1213, RFC1317

  • Time Management

    NTP Client

  • Console Port

    RS-232 (TxD, RxD, GND), 8-pin RJ45 (115200, n, 8, 1)

  • No. of Ports

    1

  • Connector

    DB9 male

  • Serial Standards

    RS-232/422/485

  • Baudrate

    50 bps to 921.6 kbps

  • Data Bits

    7, 8

  • Parity

    None
    Even
    Odd
    Space
    Mark

  • Stop Bits

    1, 2

  • Flow Control

    RTS Toggle (RS-232 only)
    RTS/CTS

  • RS-485 Data Direction Control

    Automatic Data Direction Control (ADDC)

  • Pull High/Low Resistor for RS-485

    1 kilo-ohm, 150 kilo-ohms

  • Terminator for RS-485

    120 ohms

  • Isolation

    2 kV (built-in)

  • RS-232

    TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND

  • RS-422

    Tx+, Tx-, Rx+, Rx-, GND

  • RS-485-2w

    Data+, Data-, GND

  • RS-485-4w

    Tx+, Tx-, Rx+, Rx-, GND

  • Configuration Options

    Serial Console

  • Industrial Protocols

    PROFIBUS DP-V0 Slave
    Modbus RTU/ASCII Master
    Modbus RTU/ASCII Slave

  • Mode

    Master, Slave

  • Functions Supported

    1, 2, 3, 4, 5, 6, 15, 16, 23

  • Max. No. of Commands

    128

  • Input Data Size

    2048 bytes

  • Output Data Size

    2048 bytes

  • Mode

    Client (Master), Server (Slave)

  • Functions Supported

    1, 2, 3, 4, 5, 6, 15, 16, 23

  • Max. No. of Client Connections

    16

  • Max. No. of Server Connections

    32

  • Max. No. of Commands

    128

  • Input Data Size

    2048 bytes

  • Output Data Size

    2048 bytes

  • Industrial Protocols

    PROFIBUS DP

  • No. of Ports

    1

  • Connector

    DB9 female

  • Baudrate

    9600 bps to 12 Mbps

  • Isolation

    2 kV (built-in)

  • Signals

    PROFIBUS D+, PROFIBUS D-, RTS, Signal Common, 5V

  • Rotary Switch

    PROFIBUS addresses 0-99 (addresses 100-125 supported through software configuration)

  • Mode

    DP-V0 Slave

  • Max. No. of Master Connections

    1

  • Max. No. of PROFIBUS I/O Modules

    24

  • Input Data Size

    244 bytes

  • Output Data Size

    244 bytes

  • Mode

    IO Device

  • Max. No. of IO Controller Connections

    1 (for read/write)

  • Input Data Size

    512

  • Output Data Size

    512

  • Mode

    Adapter

  • CIP Objects Supported

    Identity
    Message Router
    Assembly
    Connection Manager
    TCP/IP interface
    Ethernet link
    Port

  • Max. No. of Scanner Connections

    1 (for read-only), 1 (for read/write)

  • Input Data Size

    496 bytes

  • Output Data Size

    496 bytes

  • microSD Slot

    Up to 32 GB (SD 2.0 compatible)

  • Input Voltage

    12 to 48 VDC

  • Input Current

    416 mA @ 12 VDC

  • Power Connector

    Spring-type Euroblock terminal

  • Contact Current Rating

    Resistive load: 2 A @ 30 VDC

  • Housing

    Metal

  • IP Rating

    IP30

  • Dimensions

    45.8 x 105 x 134 mm (1.8 x 4.13 x 5.28 in)

  • Weight

    589 g (1.30 lb)

  • Operating Temperature

    MGate 5111: 0 to 60°C (32 to 140°F)
    MGate 5111-T: -40 to 75°C (-40 to 167°F)

  • Storage Temperature (package included)

    -40 to 85°C (-40 to 185°F)

  • Ambient Relative Humidity

    5 to 95% (non-condensing)

  • EMC

    EN 61000-6-2/-6-4

  • EMI

    CISPR 32, FCC Part 15B Class A

  • EMS

    IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
    IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
    IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
    IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
    IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m
    IEC 61000-4-8 PFMF

  • Safety

    EN 62368-1
    UL 61010-2-201

  • Hazardous Locations

    ATEX
    Class I Division 2
    IECEx

  • Freefall

    IEC 60068-2-32

  • Shock

    IEC 60068-2-27

  • Vibration

    IEC 60068-2-6
    IEC 60068-2-64

  • Time

    718,131 hrs

  • Standards

    Telcordia SR332

Software, Firmware, and Drivers

FILTER

Name Type Checksum Version Operating System Release Date
Software Package for MXview One Series (Windows version)
300.8 MB
Software Package
SHA-512
v1.4.1
  • Windows 10
  • Windows 11
  • Windows Server 2016
  • Windows Server 2019
  • Windows Server 2022
Sep 20, 2024 Sep 20, 2024 Release notes
Software Package for MXview One Series (Linux version)
404.8 MB
Software Package
SHA-512
v1.4.1
  • Ubuntu 18.04
  • Ubuntu 20.04
  • Ubuntu 22.04
Sep 20, 2024 Sep 20, 2024 Release notes
MXview One plugin (Windows)
19.3 MB
Software Package
SHA-512
v1.4
  • Windows 10
  • Windows 11
  • Windows Server 2016
  • Windows Server 2019
  • Windows Server 2022
Jun 11, 2024 Jun 11, 2024 Release notes
MXview One plugin (Linux)
21.9 MB
Software Package
SHA-512
v1.4
  • Ubuntu 18.04
  • Ubuntu 20.04
  • Ubuntu 22.04
Jun 11, 2024 Jun 11, 2024 Release notes
MXconfig plugin (non-Java version)
1.1 MB
Software Package
SHA-512
v1.3
  • Windows 10
  • Windows 7
  • Windows Server 2016
  • Windows Server 2019
Apr 26, 2024 Apr 26, 2024 Release notes
Firmware for MGate 5111 Series
8.5 MB
Firmware
SHA-512
v2.1
Sep 26, 2023 Sep 26, 2023 Release notes
MXconfig Plugin
3.3 MB
Software Package
SHA-512
v1.4
  • Windows 10
  • Windows 7
  • Windows Server 2008 R2
  • Windows Server 2012
  • Windows Server 2012 R2
Jul 17, 2023 Jul 17, 2023 Release notes
Moxa CLI Configuration Tool for Windows
2.0 MB
Utility
SHA-512
v1.3
  • Windows 10
  • Windows 11
  • Windows 2000
  • Windows 7
  • Windows 8
  • Windows 8.1
  • Windows Server 2008 R2
  • Windows Server 2012
  • Windows Server 2012 R2
  • Windows Server 2016
  • Windows Server 2019
  • Windows Server 2022
Jun 29, 2023 Jun 29, 2023 Release notes
Moxa CLI Configuration Tool for Linux
11.6 MB
Utility
SHA-512
v1.3
  • Linux Kernel 2.6.x
  • Linux Kernel 3.x
  • Linux Kernel 4.x
  • Linux Kernel 5.x
Jun 29, 2023 Jun 29, 2023 Release notes
Device Search Utility
2.2 MB
Utility
SHA-512
v2.7
  • Windows 10
  • Windows 11
  • Windows 2000
  • Windows 7
  • Windows 8
  • Windows 8.1
  • Windows 95
  • Windows 98
  • Windows 98 SE
  • Windows NT
  • Windows Server 2003
  • Windows Server 2008
  • Windows Server 2008 R2
  • Windows Server 2012
  • Windows Server 2012 R2
  • Windows Server 2016
  • Windows Server 2019
  • Windows Server 2022
  • Windows Vista
  • Windows XP
Jun 28, 2023 Jun 28, 2023 Release notes
MXview plugin
32.8 MB
Software Package
SHA-512
v1.4
  • Windows 10
  • Windows 7
  • Windows Server 2012 R2
  • Windows Server 2016
  • Windows Server 2019
May 02, 2023 May 02, 2023 Release notes
EtherNet/IP Adapter EDS file for MGate 5111 Series
11.5 KB
Software Package
SHA-512
v2.1
Sep 02, 2019 Sep 02, 2019 Release notes
PROFIBUS GSD file for MGate 5111 Series
4.8 KB
Software Package
SHA-512
v1.0
Jan 19, 2018 Jan 19, 2018 Release notes
MIB file for MGate 5111 Series
15.2 KB
Software Package
SHA-512
v1.0
Jan 18, 2018 Jan 18, 2018 Release notes
Software Package for MGate 5111 Series (GSDML file)
25.4 KB
Software Package
SHA-512
v1.0
Jan 18, 2018 Jan 18, 2018 Release notes

Support Documents

Name Type Version Release Date
FOSS Statement for MGate 5000 Series
852.4 KB
Declaration v1.1 Sep 27, 2024 Sep 27, 2024
Tech Note: Configuring and Monitoring with MXview One/MXview and MXconfig (non-java and java) Plugins
2.1 MB
Tech Note v1.0 May 07, 2024 May 07, 2024
Datasheet for MGate 5111 Series
716.9 KB
Datasheet v1.1 Apr 23, 2024 Apr 23, 2024
Manual for MGate 5111 Series
6.4 MB
Manual v1.2 Sep 20, 2023 Sep 20, 2023
Tech Note: The Security Hardening Guide for MGate 5000 Series
1.3 MB
Tech Note v2.2 Aug 16, 2023 Aug 16, 2023
QIG for MGate 5111 Series
693.8 KB
QIG v1.3 May 18, 2023 May 18, 2023
Tech Note: How to Use the TIA Portal to Set a Siemens PLC and the MGate 5111
1.9 MB
Tech Note v1.0 Dec 28, 2017 Dec 28, 2017
2D CAD for Mgate 5111
133.0 KB
2D CAD Dec 22, 2017 Dec 22, 2017

Available Models (2)

Show Images
moxa-mgate-5111-image.jpg | MoxaMGate 5111moxa-mgate-5111-t-image.jpg | MoxaMGate 5111-T
Operating Temp.0 to 60°C-40 to 75°C
Add to QuoteView BagAdd to QuoteView Bag

Secure Your Edge Connectivity in Every Aspect

Learn More

product image

Buy online from distributors

Added To Bag
You have some items waiting in your bag; click here to finish your quote!
Feedback