OnCell G3101/G3201 Series

Compact quad-band GSM/GPRS IP gateways

moxa-oncell-g3101-g3201-series-image-1-(1).jpg | Moxa
moxa-oncell-g3101-g3201-series-image-2-(1).jpg | Moxa
moxa-oncell-g3101-g3201-series-image-3-(1).jpg | Moxa

Features and Benefits

  • Universal quad-band GSM/GPRS 850/900/1800/1900 MHz
  • Desktop or DIN-rail installation
  • Connect Ethernet and serial devices
  • Centralized private IP management software with OnCell Central Manager
  • Choice of configuration methods, including web console, serial console, and Telnet

Certifications

  • moxa-ul-listed-certification-logo-image.png | Moxa
  • moxa-ce-certification-logo-image.png | Moxa
  • moxa-fcc-certification-logo-image.png | Moxa
 
Contact Sales

Introduction

The OnCell G3111/G3151/G3211/G3251 are cellular IP gateways that can conveniently and transparently connect up to two devices to a cellular network, allowing you to connect serial devices to your existing Ethernet with only basic configuration. To ensure zero data loss and on-demand cellular communication, OnCell devices are integrated with the GuaranLink function.

The G3111/G3151/G3211/G3251 cellular IP gateways are compact, and can be placed on a desk or mounted on a DIN rail. The products come with a 12 to 48 VDC power input and have 2 kV EFT/surge protection to allow the use of different types of field power sources. The serial ports are also protected by 15 kV ESD line protection to keep your system safe from unexpected electrical discharges.

  • Cellular Standards

    GSM, GPRS

  • Band Options

    Quad-band GSM/GPRS 850 MHz / 900 MHz / 1800 MHz / 1900 MHz

  • GPRS Data Rates

    85.6 kbps DL, 43 kbps UL

  • GPRS Multi-Slot Class

    10

  • GPRS Terminal Device Class

    Class B

  • GPRS Coding Schemes

    CS1 to CS4

  • Cellular Antenna Connectors

    1 SMA female

  • No. of SIMs

    1

  • SIM Control Voltage

    3 V

  • 10/100BaseT(X) Ports (RJ45 connector)

    1

  • Total Port Count

    1

  • Management

    ARP, DDNS, DHCP/BOOTP, DNS Relay, HTTP, SMTP, SNMPv1/v2c/v3, TCP/IP, Telnet, UDP, Web Console, Wireless Search Utility, Serial Console, Telnet Console, Remote SMS Control, OnCell Central Manager, GuaranLink

  • Routing

    NAT, Port forwarding, WAN IP Filtering

  • Security

    HTTPS/SSL, SSH

  • Time Management

    SNTP

  • Filter

    ICMP

  • Serial Standards

    OnCell G3211/G3111: RS-232
    OnCell G3151/G3251: RS-232/422/485

  • Data Bits

    5, 6, 7, 8

  • Stop Bits

    1, 1.5, 2

  • Parity

    None, Even, Odd, Space, Mark

  • Flow Control

    RTS/CTS, XON/XOFF

  • Baudrate

    50 bps to 921.6 kbps

  • RS-232

    TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND

  • RS-422

    Tx+, Tx-, Rx+, Rx-, GND

  • RS-485-2w

    Data+, Data-, GND

  • RS-485-4w

    Tx+, Tx-, Rx+, Rx-, GND

  • Standards

    Ethernet Modem mode
    Real COM mode
    RFC2217 mode
    TCP Client mode
    TCP Server mode
    UDP mode
    SMS Tunnel
    Reverse Real COM

  • Input Voltage

    12 to 48 VDC

  • Power Connector

    Power jack

  • Input Current

    0.9 A @ 12 VDC, 0.23 A @ 48 VDC

  • Housing

    Aluminum

  • IP Rating

    IP30

  • Dimensions

    77 x 111 x 26 mm (3.03 x 4.37 x 1.02 in)

  • Weight

    OnCell G3151/G3111: 170 g (0.38 lb)
    OnCell G3211/G3251: 190 g (0.42 lb)

  • Operating Temperature

    -30 to 55°C (-22 to 131°F)

  • Storage Temperature (package included)

    -40 to 75°C (-40 to 167°F)

  • Ambient Relative Humidity

    5 to 95% (non-condensing)

  • Safety

    UL 60950-1

  • EMC

    EN 55032/24

  • EMI

    CISPR 32, FCC Part 15B Class A

  • EMS

    IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
    IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
    IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV
    IEC 61000-4-5 Surge: Power: 1 kV; Signal: 1 kV
    IEC 61000-4-6 CS: 10 V
    IEC 61000-4-8 PFMF

  • Radio Frequency

    FCC Part 22H, FCC Part 24E, EN 301 489-1, EN 301 489-7, EN 301 511, PTCRB (OnCell G3151 only)

  • Time

    1,483,420 hrs

  • Standards

    Telcordia SR332

Software, Firmware, and Drivers

FILTER

Name Type Version Operating System Release Date
Windows Driver Manager (for Windows 7, Server 2008, or later)
2.8 MB
Driver v3.1
  • Windows 10
  • Windows 7
  • Windows 8
  • Windows 8.1
  • Windows Server 2008 R2
  • Windows Server 2012 R2
  • Windows Server 2016
  • Windows Server 2019
2019-05-21 May 21, 2019 Release notes
Firmware for OnCell G3101/G3201 Series
2.3 MB
Firmware v1.9
2018-12-12 Dec 12, 2018 Release notes
OnCell Central Manager (32-bit)
104.7 MB
Software Package v2.3
  • Windows 10
  • Windows 7
  • Windows 8
  • Windows Server 2003
  • Windows Server 2008
  • Windows Server 2008 R2
  • Windows Server 2012
  • Windows Server 2012 R2
  • Windows Server 2016
  • Windows Server 2019
  • Windows Vista
2017-04-20 Apr 20, 2017 Release notes
OnCell Central Manager (64-bit)
112.4 MB
Software Package v2.3
  • Windows 10
  • Windows 7
  • Windows 8
  • Windows Server 2003
  • Windows Server 2008
  • Windows Server 2008 R2
  • Windows Server 2012
  • Windows Server 2012 R2
  • Windows Server 2016
  • Windows Server 2019
  • Windows Vista
2017-04-20 Apr 20, 2017 Release notes
OnCell Windows Driver Manager (WHQL certified)
1.8 MB
Driver v1.19
  • Windows 10
  • Windows 7
  • Windows 8
  • Windows 8.1
  • Windows Server 2008 R2
  • Windows Server 2012
  • Windows Server 2012 R2
  • Windows Server 2016
2016-07-30 Jul 30, 2016 Release notes
Library for OnCell G3101/G3201 Series
177.7 KB
Library v1.12
2015-07-30 Jul 30, 2015 Release notes
OnCell Search Utility
1.0 MB
Utility v1.14
2013-12-17 Dec 17, 2013 Release notes
Driver for OnCell G3101/G3201 Series (Real TTY)
285.3 KB
Driver v1.0
  • Windows 2000
  • Windows 95
  • Windows 98
  • Windows ME
  • Windows NT
  • Windows Server 2003
  • Windows XP
2010-11-20 Nov 20, 2010 Release notes

Support Documents

Name Type Version Release Date
Datasheet for OnCell G3101/G3201 Series
699.2 KB
Datasheet v1.2 2019-08-29 Aug 29, 2019
Manual for OnCell G3101/G3201 Series
11.9 MB
Manual v4.0 2018-01-13 Jan 13, 2018
OnCell Central Manager User's Manual
4.0 MB
Manual v1.1 2017-05-25 May 25, 2017
QIG for OnCell G3101/G3201 Series
830.7 KB
QIG v2.1 2016-08-13 Aug 13, 2016
2D CAD for OnCell G3111/G3151
1.1 MB
2D CAD 2016-08-11 Aug 11, 2016
2D CAD for OnCell G3211/G3251
1.1 MB
2D CAD 2016-08-11 Aug 11, 2016

Available Models (2)

Show Images
moxa-oncell-g3151-image.jpg | MoxaOnCell G3151moxa-oncell-g3251-image.jpg | MoxaOnCell G3251
Cellular StandardGSM/GPRSGSM/GPRS
GPRS Band850/900/1800/1900 MHz850/900/1800/1900 MHz
Operating Temp.-30 to 55°C-30 to 55°C
No. of Serial Ports12
Serial StandardsRS-232/422/485RS-232/422/485
Add to QuoteView BagAdd to QuoteView Bag
Added To Bag

OnCell G3101/G3201 Series

OnCell G3151

moxa-oncell-g3151-image.jpg | Moxa

Buy online from our distributors

OnCell G3101/G3201 Series

OnCell G3251

moxa-oncell-g3251-image.jpg | Moxa

Buy online from our distributors