As of June 15, 2022, this site no longer supports Internet Explorer. Please use another browser for the best experience on our site.

ioPAC 6500 Series (65M) I/O Modules

I/O modules for modular programmable IIN controllers

moxa-iopac-6500-series-65m-i-o-modules-image-(1).jpg | Moxa
moxa-iopac-6500-series-65m-i-o-modules-image-1-(1).jpg | Moxa

Features and Benefits

  • Error-proof design to prevent erroneous installations
  • Tool-free hardware installation and hot-swap design for maximizing operation efficiency
  • Fully modular design for maximum deployment flexibility

Certifications

  • moxa-ce-certification-logo-image.png | Moxa
  • moxa-fcc-certification-logo-image.png | Moxa
  • moxa-ul-listed-certification-logo-image.png | Moxa
 
Contact Sales

Introduction

The ioPAC 6500 Series (also referred to as Intelligent Integrated Node or IIN) is an advanced Linux-based RTU featuring a built-in Layer-2 managed switch. Equipped with an Arm Cortex-A53 quad-core CPU, the ioPAC 6500 Series delivers robust performance.

Error–proof Design With Arrow Pins

The arrow-pin design on the I/O and terminal block (TB) modules prevents erroneous installations. Each I/O module has its own TB module with a unique TB arrow ID.

Fully Modular Design

The ioPAC 6500 Series features a unique Lego-like mechanical design that allows for flexible deployment while minimizing installation efforts. The series can be divided into the components: Backplane modules, power modules, communication modules, expansion modules, CPU modules, I/O modules, and terminal-block modules.

  • Digital Input Channels

    65M-1900-CT-T: 32

  • Digital Output Channels

    65M-2901-CT-T: 32

  • Analog Input Channels

    65M-3600-CT-T: 16 (current)
    65M-3610-CT-T: 16 (voltage)
    65M-3800H-CT-T: 8 (HART)

  • Analog Output Channels

    65M-4820-CT-T: 8

  • Serial Channels

    65M-5801-CT-T: 8

  • Isolation

    65M-3600-CT-T/65M-3610-CT-T/65M-4820-CT-T/65M-5801-CT-T:
    - Between signal and system: 3k VDC
    - Between groups: 1k VDC per min
    All other models:
    - Between signal and system: 3k VDC

  • I/O Type

    Sink
    (Internal/external field circuit supply for dry contact)

  • I/O Mode

    DI or event counter
    (channels 1 to 8, group configurable by software)

  • Internal Field Circuit Supply Voltage

    24 VDC
    22.8 to 25.2 VDC

  • Internal Field Circuit Supply Current

    125 mA (max.)
    (Only for dry contact)

  • Input Voltage

    On: 11 to 30 VDC
    Off: 0 to 5 VDC

  • Input Current (voltage on)

    2.35 mA ± 20% per channel

  • Counter Frequency

    Square wave: 0 to 10 kHz

  • Digital Filtering Time Interval

    Software configurable

  • Diagnostics

    Input Wire-break Detection (current: 50 µA max., delay: 20 ms)
    Internal Field Circuit Supply Detection (17.5 VDC, 16 to 19 VDC)

  • I/O Type

    Source

  • I/O Mode

    DO or pulse output
    (channel 1 to 8, group configurable by software)

  • Common Power Input Voltage

    24 VDC
    19.2 to 28.8 VDC

  • Common Power Input Current

    6.4 A (max.)

  • Load Current

    200 mA/channel (typ.)
    500 mA/channel (max.)

  • Pulse Duration

    500 μs

  • Protection

    Output Short-circuit Protection
    Common Power Input Over-voltage Protection
    Inductive Load Shutdown Voltage Protection

  • Diagnostics

    Wire Break Detection (on state, output current < 3 mA)
    Wire Break Detection (off state, output load impedance > 58 kilo-ohms)
    Output Short-Circuit Detection (output current > 0.87 A, range: 0.64 to 1.2 A)
    External Power Detection (17.5 VDC, 16 to 19 VDC)
    Failsafe Configuration (hold last/failsafe state)

  • I/O Mode

    65M-3600-CT-T: Current
    65M-3610-CT-T: Voltage
    65M-3800H-CT-T: HART

  • I/O Type

    Differential

  • Input Range

    65M-3600-CT-T:
    0 to 20 mA
    4 to 20 mA
    65M-3610-CT-T:
    0 to 10 V
    1 to 5 V
    65M-3800H-CT-T:
    4 to 20 mA

  • Overload Permitted on Inputs

    65M-3600-CT-T: ±30 mA
    65M-3610-CT-T: ±12 V
    65M-3800H-CT-T: 30 mA

  • Internal Loop Power Supply Current

    65M-3600-CT-T:
    200 mA / Group (max.)
    65M-3800H-CT-T:
    500 mA (max.)
    (only for 2-wire connection)

  • Internal Loop Power Supply Voltage

    65M-3600-CT-T:
    24 VDC
    22.8 to 25.2 VDC

  • Converter Resolution

    16 bits

  • Measurement Resolution

    65M-3600-CT-T:
    2 μA (0 to 20 mA)
    1.6 μA (4 to 20 mA)
    65M-3610-CT-T:
    1 mV (0 to 10 V)
    0.4 mV (1 to 5 V)
    65M-3800H-CT-T:
    1.6 μA (4 to 20 mA)

  • Accuracy

    ±0.1% FSR @ 25°C
    ±0.3% FSR @ -40 to 75°C

  • Conversion Time

    100 ms

  • Rejection Ratio

    Normal mode: > 60 dB @ 60 Hz (min.), conversion time: 100 ms
    Common mode: > 90 dB @ 60 Hz (min.), conversion time: 100 ms

  • Input Impedance

    65M-3800H-CT-T: 250 ohms
    65M-3600-CT-T: 250 ohms
    65M-3610-CT-T: 1 mega-ohms

  • Diagnostics

    65M-3800H-CT-T:
    Input Wire-break
    Input Short-circuit
    Input Underflow/Overflow Detection
    65M-3600-CT-T:
    Internal Loop Power Detection (17.5 VDA, 16 to 19 VDC)
    Input Short-circuit Detection
    65M-3600-CT-T (in 4 to 20 mA mode):
    Input Wire-break Detection (delay: 0.8 s)
    65M-3610-CT-T:
    Input Wire-break Detection (delay:1.6 s max)

  • I/O Mode

    Voltage/Current

  • Output Range

    0 to 10 V
    1 to 5 V
    0 to 20 mA
    4 to 20 mA

  • Converter Resolution

    16-bit

  • Output Resolution

    0.1 mV (0 to 10 V)
    0.4 mV (1 to 5 V)
    2 μA (0 to 20 mA)
    1.6 μA (4 to 20 mA)

  • Accuracy

    ±0.1% FSR @ 25°C
    ±0.3% FSR @ -40 to 75°C

  • Output Refresh Time

    16 ms

  • Output Impedance

    Voltage mode:
    1 kilo-ohms (min.)
    Current mode:
    750 ohms (max.)

  • Diagnostics

    Output Short-circuit Detection (voltage)
    Failsafe Configuration (hold last/failsafe state)
    Output Wire-break Detection (current)

  • Serial Standards

    RS-232, RS-422, RS-485-2w

  • Baudrate

    300, 600, 1200, 1800, 2400, 4800, 9600, 19200, 38400, 57600, and 115200 bps

  • Data Bits

    7, 8

  • Stop Bits

    1, 2

  • Parity

    None
    Even
    Odd

  • Flow Control

    RTS/CTS, XON/XOFF

  • Serial Signals

    RS-232: TxD, RxD, RTS, CTS, GND
    RS-422: Tx+, Tx-, Rx+, Rx-, GND
    RS-485-2w: Data+, Data-, GND

  • ID

    65M-TB-1900-CT-T: D1
    65M-TB-2901-CT-T: D2
    65M-TB-3600-CT-T: A1
    65M-TB-3610-CT-T: A2
    65M-TB-3800H-CT-T: A3
    65M-TB-4820-CT-T: A5
    65M-TB-5801-CT-T: F1
    Note: Terminal blocks need to be purchased separately. See the Accessories section/list for details.

  • Connector

    Screw-fastened terminal block

  • Dimensions

    42.3 x 102.38 x 80.8 mm (1.67 x 4.03 x 3.18 in)

  • Weight

    164 g (0.36 lb)

  • System Power

    65M-1900-CT-T/65M-2901-CT-T:
    0.068 A @ 12 VDC
    65M-3610-CT-T/65M-4820-CT-T:
    0.069 A @ 12 VDC
    65M-3600-CT-T:
    0.073 A @ 12 VDC
    65M-3800H-CT-T:
    0.072 A @ 12 VDC
    65M-5801-CT-T:
    0.143 @ 12 VDC

  • Field Power

    65M-1900-CT-T:
    0.019 A @ 24 VDC (without internal field circuit supply)
    0.115 A @ 24 VDC (32-channel dry contact with internal field circuit supply)
    65M-2901-CT-T:
    0.005 A @ 24 VDC
    65M-3600-CT-T:
    0.053 A @ 24 VDC (without internal loop power)
    0.466 A @ 24 VDC (16-channel 20 mA input with internal loop power)
    65M-3610-CT-T:
    0.038 A @ 24 VDC
    65M-3800H-CT-T:
    0.05 A (max.) @ 24 VDC (without internal loop power)
    0.25 A (max.) @ 24 VDC (8-channel 4 to 20 mA input with internal loop power all in 20 mA)
    0.66 A (max.) @ 24 VDC (500 mA input with internal loop power)
    65M-4820-CT-T:
    0.022 A @ 24 VDC (without external load)
    0.266 A @ 24 VDC (4-channel 20 mA output)
    65M-5801-CT-T:
    0.11 A @ 24 VDC

  • Housing

    Plastic

  • Dimensions

    42 x 116 x 130 mm (1.65 x 4,57 x 5.12 in)

  • Weight

    65M-3610-CT-T: 250 g (0.55 lb)
    65M-1900-CT-T: 253 g (0.56 lb)
    65M-2901-CT-T: 254 g (0.56 lb)
    65M-4820-CT-T: 257 g (0.57 lb)
    65M-5801-CT-T: 259 g (0.57 lb)
    65M-3800H-CT-T: 262 g (0.58 lb)
    65M-3600-CT-T: 267 g (0.59 lb)

  • Operating Temperature

    -40 to 75°C (-40 to 167°F)
    Note: Proper airflow is required in an environment with temperature > 65°C.

  • Storage Temperature (package included)

    -40 to 85°C (-40 to 185°F)

  • Ambient Relative Humidity

    5 to 95% (non-condensing)

  • Altitude

    Up to 2000 meters Please contact Moxa if you require products guaranteed to function properly at higher altitudes.

  • EMC

    EN 55032/35
    EN 61000-6-2/-6-4

  • EMI

    CISPR 32, FCC Part 15B Class A

  • EMS

    IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
    IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
    IEC 61000-4-4 EFT: Power: (DC) 1 kV; Signal: 1 kV
    IEC 61000-4-5 Surge: Power: (DC) 0.5 kV L-N, 1 kV L/N-PE; Signal: 1 kV; IO: 0.5 kV
    IEC 61000-4-6 CS: Power: (DC) 10 V; Signal: 10 Vrms
    IEC 61000-4-8 PFMF: 30 A/m

  • Safety

    UL 61010-1
    UL 61010-2-201

  • Shock

    IEC 60068-2-27
    Half sine wave; acceleration: 15 g; time: 11 ms

  • Vibration

    IEC 60068-2-6
    DIN-rail mounted:
    7 mm peak-peak (p-p) (2 to 8.42 Hz), 1 g (8.42 to 150 Hz)
    Rack mounted (with optional kit):
    7 mm peak-peak (p-p) (2 to 8.42 Hz), 0.5 g (8.42 to 150 Hz)

  • Time

    65M-5801-CT-T: 2,310,512 hrs
    65M-3610-CT-T: 1,885,953 hrs
    65M-4820-CT-T: 1,874,152 hrs
    65M-1900-CT-T: 2,057,118 hrs
    65M-2901-CT-T: 2,007,795 hrs
    65M-3600-CT-T: 1,686,798 hrs
    65M-3800H-CT-T: 1,016,573 hrs

  • Standards

    Telcordia Standard SR-332

Support Documents

Name Type Version Release Date
ioPAC 6500 Series User Manual
25.7 MB
Manual v1.1 Nov 07, 2025 Nov 07, 2025
Datasheet for ioPAC 6500 Series (65M) I/O Modules
2.4 MB
Datasheet v1.1 Nov 07, 2025 Nov 07, 2025
ioPAC 6500 Series (65M) I/O Modules HART Module Configuration Manual (PACTware)
3.0 MB
Manual v1.0 Nov 07, 2025 Nov 07, 2025
QIG for ioPAC 6500 Series (65M) I/O Modules
1.6 MB
QIG v1.0 Mar 17, 2025 Mar 17, 2025

Available Models (7)

Show Images
moxa-65m-2901-ct-t-image.jpg | Moxa65M-2901-CT-Tmoxa-65m-5801-ct-t-image.jpg | Moxa65M-5801-CT-Tmoxa-65m-3800h-ct-t-image.jpg | Moxa65M-3800H-CT-Tmoxa-65m-1900-ct-t-image.jpg | Moxa65M-1900-CT-T
No. of I/O InterfacesDOs x 32Serial Ports x 8AIs x 8 (HART)DIs x 32
Digital Inputs/Outputs24 VDC24 VDC
Analog Inputs/Outputs4 to 20 mA
HARTenable
disable (default)
Operating Temperature-40 to 75°C-40 to 75°C-40 to 75°C-40 to 75°C
Add to QuoteView BagAdd to QuoteView BagAdd to QuoteView BagAdd to QuoteView Bag
moxa-65m-3610-ct-t-image.jpg | Moxa65M-3610-CT-Tmoxa-65m-4820-ct-t-image.jpg | Moxa65M-4820-CT-Tmoxa-65m-3600-ct-t-image.jpg | Moxa65M-3600-CT-T
No. of I/O InterfacesAIs x 16AOs x 8AIs x 16
Digital Inputs/Outputs
Analog Inputs/Outputs0 to 10 V
1 to 5 V
0 to 10 V
1 to 5 V
0 to 20 mA
4 to 20 mA
0 to 20 mA
4 to 20 mA
HART
Operating Temperature-40 to 75°C-40 to 75°C-40 to 75°C
Add to QuoteView BagAdd to QuoteView BagAdd to QuoteView Bag

product image

Buy online from distributors

Added To Bag
You have some items waiting in your bag; click here to finish your quote!
Feedback