As of June 15, 2022, this site no longer supports Internet Explorer. Please use another browser for the best experience on our site.
MOXA

Rugged Controllers & I/Os

Rail, wind power, and offshore applications demand system reliability and stability, even in harsh environments. Our rugged controllers and I/O products are designed to perform in extreme conditions while providing versatile data acquisition and control capabilities.

LIC-IINxpress-NEW
ioPAC 6500 Series

IINxpress IDE standard function license

System Performance
  • Max. No. of Control Units

    • 1
  • Max. No. of Expansion Units

    • 4
  • Max. No. of Power Backplanes Per Unit

    • Control and expansion units:
      1 (1/ 2 slots)
  • Max. No. of CPU Backplanes Per Unit

    • Control unit:
      1 (1/2 slots)
  • Max. No. of Communication Backplanes Per Unit

    • Control unit:
      1 (1/2 slots)
  • Max. No. of I/O Backplanes Per Unit

    • Control and expansion units:
      2 (2/4 slots)
  • Max. No. of Expansion Backplanes Per Unit

    • Control and expansion units:
      1 (1/2 slots)
Physical Characteristics
  • Housing

    • Plastic
  • Installation

    • DIN-rail mounting
      Rack mounting (with optional kit)
Environmental Limits
  • Operating Temperature

    • -40 to 75°C (-40 to 167°F)
      Note: Proper airflow is required in an environment with temperature > 65°C
  • Storage Temperature (package included)

    • -40 to 85°C (-40 to 185°F)
  • Ambient Relative Humidity

    • 5 to 95% (non-condensing)
  • Altitude

    • 2000 m
Standards and Certifications
  • EMC

    • EN 55032/35
      EN 61000-6-2/-6-4
  • EMI

    • CISPR 32, FCC Part 15B Class A
  • EMS

    • IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
      IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
      IEC 61000-4-4 EFT: Power: (DC) 1 kV; Signal: 1 kV
      IEC 61000-4-5 Surge: Power: (DC) 0.5 kV L-N, 1 kV L/N-PE; Signal: 1 kV; IO: 0.5 kV
      IEC 61000-4-6 CS: Power: 10 V; Signal: 10 Vrms
      IEC 61000-4-8 PFMF: 30 A/m
  • Safety

    • UL 61010-1
      UL 61010-2-201
  • Shock

    • IEC 60068-2-27
      Half sine wave; acceleration: 15 g; time: 11 ms
  • Vibration

    • IEC 60068-2-6
      DIN-rail mounted:
      7 mm peak-peak (p-p) (2 to 8.42 Hz), 1 g (8.42 to 150 Hz)
      Rack mounted (with optional kit):
      7 mm peak-peak (p-p) (2 to 8.42 Hz), 0.5 g (8.42 to 150 Hz)
  • Package Vibration Test

    • ISTA 1A
  • Package Drop Test

    • ISTA 1A
MTBF
  • Standards

    • Telcordia Standard SR-332
  • Time

    • See the datasheets for the modules for details.
Warranty
Added To Bag
You have some items waiting in your bag; click here to finish your quote!
Feedback